hitachi excavator fuse box location

1- LAMP 20A

2- WIPER 10A

3- HEATER 20A

4- ELECTROMAGNET 10A

5- OPTIONAL 1 5A

6- OPTIONAL 2 10A

7- AUTOMATIC LUBRICATION PUMP 10A

8- ECM 30A

9- BACKUP POWER 10A

10- CONTROLLER 5A

11- HORN 10A

12- INTERIOR LIGHTING/RADIO 5A

13- cigarette lighter 10A

14- FUEL PUMP 15A

15- ADDITIONAL SLAVE. EQUIPMENT.10A

16- Glow Plug RELAY 5A

17- AIR CONDITIONER 5A

18- POWER SUPPLY 5A

19- SWITCH PANEL 5A

20- OPTIONAL 3 5A

Hitachi ZAXIS 120-3 class

10- CONTROLLER5A9- BACKUP10A8- ECM30A7- LUBRICATOR10A6- OPTION210A5- OPTION15A4- SOLENOID10A3- HEATER20A2- WIPER10A1- LAMP20A

20- OPTION35A19- SW. BOX5A18- POWER ON5A17- AIRCON.5A16- GLOW RELAY5A15- AUXILIARY10A14- FUEL PUMP5A13- LIGHTER10A12- ROOM LAMP/RADIO5A11- HORN10A

Hitachi ZAXIS 120-3 class Operator's Manual Download

FUSE CHECK

 

The integrity of a fuse string is extremely difficult to verify by visual inspection alone. To test the fuses, use a tester following the procedure described below.

1. Set the electrical circuit breaker to the ON position.

When the electrical system switch is set to the ON position, current from the electrical system switch terminal M is applied to the battery relay, thus energizing all circuits except the glow plug relay circuit. (See circuit diagram).

2. Remove the fuse block cover. Install the tester. (Measurement range: 0 to 30 V)

3. Ground the negative tester lead on the machine frame. Alternately touch the clamps located at a distance from the axis of the fuse block with the positive probe of the tester one at a time. If the fuses are intact, the tester will display a voltage value of 20-25 V (battery voltage).

 

NOTE: All terminals located along the axis of the fuse block are connected to the power supply, while terminals located away from the axis of the fuse block are connected to the load (consumers). For this reason, check the fuses using the same method, except for checking the glow plug relay fuses. Check the filament relay circuit fuse with the electrical circuit breaker in the ON position following the procedure in step 3.