Claas Error Codes List

LIST OF ERROR CODES

MFA (A100)
TR1 (A57-1)
TR2 (A57-2)
TR3 (A57-3)
REH (A58)
SFA (A102)
BDG (A103)
ENG (A15)
MFT (A30)
EXT (A62)
DBD (A101)
HYD PVV (A60) 

Types of CIS alarms

Fault is indicated by LEDs (A1 to A24), a fault code on CIS display and / or acoustic alarm signal. In case of medium and severe faults, in addition, the STOP lamp lights up traffic informant. There are three different types of emergency alarms:

Severe / permanent failure Emergency Signal

Malfunction medium / three short alarms

Mild Defect / One Short Emergency Signal

  • DESCRIPTION
  • TECHNICAL DESCRIPTION
  • CAN MESSAGING
  • TECHNICAL SPECIFICATIONS 
  • FUNCTIONAL LOGIC
  • SCHEMATIC DIAGRAM
  • TECHNICAL SPECIFICATIONS 
  • FUNCTIONAL LOGIC
  • SCHEMATIC DIAGRAM

Claas G1 LIST OF ERROR CODES G2 CONTROL PANEL "WLP" Download

List of A/C error codes

Error

Component concerned

Type of fault

"CLAAS component number"

E0

Sensor for air temperature inside the cab

Open circuit

B086

E1

Pulsed air temperature sensor

Open circuit

B087

E2

Solar sensor

Open circuit

B224

E3

Pressure switch

Open circuit

Z021

E4

Outside air temperature switch

Open circuit

B088

E5

Sensor for air temperature inside the cab

Short circuit

B086

E6

Pulsed air temperature sensor

Short circuit

B087

E7

Solar sensor

Short circuit

B224

E8

Compressor

Open circuit

Y032

E9

Outside air temperature switch

Short circuit

B088

EA

Heating power valve

Valve locked

V020

EB

Heating power valve

Bad connection

V020

EE

Motor fan regulator

Overheating

V020

 

"Cebis" Panel (MFT A30)

MFA (A100)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id7500h

MFA (A100)

Unable to read tractor
specific parameters in
EEPROM memory.

The multifunction armrest runs
in degraded mode (all options).

Check:
The MFA (A100) armrest multifunction
module.

Id7502h

MFA (A100)

Stabilized power supply 10V
of contacts too low.

The contacts of the
multifunction armrest are
inactive

Check:
The MFA (A100) armrest multifunction
module.

Id7503h

MFA (A100)

Stabilized power supply 5V
too low.

The multifunction armrest is
inactive.
The current gear is maintained.
After restarting, the gears
available are (C1) and (B1),
according to the work/transport
mode selected.

Check:
The MFA (A100) armrest multifunction
module.

Id7504h

MFA (A100)

Signal voltage specified with
the Drivestick too high.

The multifunction armrest is
inactive.
The current gear is maintained.
After restarting, the gears
available are (C1) and (B1),
according to the work/transport
mode selected.

Check:
– the Drivestick (R74).
– The MFA (A100) armrest multifunction
module.

Id7505h

MFA (A100)

Signal voltage specified with
the Drivestick too low.

The multifunction armrest is
inactive.
The current gear is maintained.
After restarting, the gears
available are (C1) and (B1),
according to the work/transport
mode selected.

Check:
– the Drivestick (R74).
– The MFA (A100) armrest multifunction
module.

Id7506h

MFA (A100)

Signal voltage specified with
hand accelerator too high.

The hand accelerator is
inactive.

Check:
– The position potentiometer of the hand
accelerator (R72).
– The MFA (A100) armrest multifunction
module.

Id7507h

MFA (A100)

Signal voltage specified by
the hand accelerator too low.

The hand accelerator is
inactive.

Check:
– The position potentiometer of the hand
accelerator (R72).
– The MFA (A100) armrest multifunction
module.

Id7508h

MFA (A100)

Signal voltage specified by
the position instruction knob
too high.

Lifting is locked. Use external
controls.

Check:
– The lifting position instruction potentiometer
(R77).
– The MFA (A100) armrest multifunction
module.

Id7509h

MFA (A100)

Signal voltage specified by
the position instruction knob
too low.

Lifting is locked. Use external
controls.

Check:
– The lifting position instruction potentiometer
(R77).
– The MFA (A100) armrest multifunction
module.

Id750Ah

MFA (A100)

Signal voltage specified with
the distributor control on line
1 too high.

Online command 1 is inactive.

Check:
– Online command of electrodistributor n°1
(R76-1).
– The MFA (A100) armrest multifunction
module.

Id750Bh

MFA (A100)

Signal voltage specified with
the online command
distributor 1 too low.

Online command 1 is inactive.

Check:
– Online command of electrodistributor n°1
(R76-1).
– The MFA (A100) armrest multifunction
module.

Id750Ch

MFA (A100)

Signal voltage specified with
the distributor control on line
2 too high.

Online command 2 is inactive.

Check:
– Online command of electrodistributor n°2
(R76-2).
– The MFA (A100) armrest multifunction
module.

Id750Dh

MFA (A100)

Signal voltage specified with
the online command
distributor 2 too low.

Online command 2 is inactive.

Check:
– Online command of electrodistributor n°2
(R76-2).
– The MFA (A100) armrest multifunction
module.

Id750Eh

MFA (A100)

Signal voltage specified with
the distributor control on line
3 too high.

Online command 3 is inactive.

Check:
– Online command of electrodistributor n°3
(R76-3).
– The MFA (A100) armrest multifunction
module.

Id750Fh

MFA (A100)

Signal voltage specified with
the online command
distributor 3 too low.

Online command 3 is inactive.

Check:
– Online command of electrodistributor n°3
(R76-3).
– The MFA (A100) armrest multifunction
module.

Id7510h

MFA (A100)

Signal voltage specified with
the distributor control on line
5 too high.

Axis 5 of the cross command
(Electropilot) is inactive.

Check:
– Cross command (Electropilot)
electrodistributor n° 5 (R75).
– The MFA (A100) armrest multifunction
module.

Id7511h

MFA (A100)

Signal voltage specified by
the cross distributor
command 5 too low.

Axis 5 of the cross command
(Electropilot) is inactive.

Check:
– Cross command (Electropilot)
electrodistributor n° 5 (R75).
– The MFA (A100) armrest multifunction
module.

Id7512h

MFA (A100)

Signal voltage specified with
the distributor control on line
4 too high.

Axis 4 of the cross command
(Electropilot) is inactive.

Check:
– Cross command (Electropilot)
electrodistributor n° 4 (R75).
– The MFA (A100) armrest multifunction
module.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7513h

MFA (A100)

Signal voltage specified by
the cross distributor
command 4 too low.

Axis 4 of the cross command
(Electropilot) is inactive.

Check:
– Cross command (Electropilot)
electrodistributor n° 4 (R75).
– The MFA (A100) armrest multifunction
module.

Id7514h

MFA (A100)

Voltage of the signal
specified by the stop lifting
too high command.

Lifting is locked. Use external
controls.

Check:
– The stop lifting contact (S184).
– The MFA (A100) armrest multifunction
module.

Id7515h

MFA (A100)

Voltage of the signal
specified by the stop lifting
too low command.

Lifting is locked. Use external
controls.

Check:
– The stop lifting contact (S184).
– The MFA (A100) armrest multifunction
module.

Id7516h

MFA (A100)

Voltage of the signal
specified by the stop lifting
incoherent command.

Lifting is locked. Use external
controls.

Check:
– The stop lifting contact (S184).
– The MFA (A100) armrest multifunction
module.

Id7517h

MFA (A100)

Voltage of the signal
specified by the lifting up too
high command.

The lifting up mode is inactive.

Check:
– The lifting up contact (S181).
– The MFA (A100) armrest multifunction
module.

Id7518h

MFA (A100)

Voltage of the signal
specified by the lifting up too
low command.

The lifting up mode is inactive.

Check:
– The lifting up contact (S181).
– The MFA (A100) armrest multifunction
module.

Id7519h

MFA (A100)

Voltage of the signal
specified by the lifting up
command incoherent.

The lifting up mode is inactive.

Check:
– The lifting up contact (S181).
– The MFA (A100) armrest multifunction
module.

Id751Ah

MFA (A100)

Voltage of the signal
specified by the lifting down
command too high.

Lifting is locked. Use external
controls.

Check:
– The lifting down contact (S182).
– The MFA (A100) armrest multifunction
module.

Id751Bh

MFA (A100)

Voltage of the signal
specified by the lifting down
too low signal.

Lifting is locked. Use external
controls.

Check:
– The lifting down contact (S182).
– The MFA (A100) armrest multifunction
module.

Id751Ch

MFA (A100)

Voltage of the signal
specified by the lifting down
command incoherent.

Lifting is locked. Use external
controls.

Check:
– The lifting down contact (S182).
– The MFA (A100) armrest multifunction
module.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id751Dh

MFA (A100)

Voltage of the signal
specified by the Hexactiv
contact too high.

The Hexactiv function is
inactive.

Check:
– The Hexactiv automation contact (S192).
– The MFA (A100) armrest multifunction
module.

Id751Eh

MFA (A100)

Voltage of the signal
specified by the Hexactiv
contact too low.

The Hexactiv function is
inactive.

Check:
– The Hexactiv automation contact (S192).
– The MFA (A100) armrest multifunction
module.

Id751Fh

MFA (A100)

Voltage of the signal
specified by the Hexactiv
contact incoherent.

The Hexactiv function is
inactive.

Check:
– The Hexactiv automation contact (S192).
– The MFA (A100) armrest multifunction
module.

Id7520h

MFA (A100)

Voltage of the signal
specified by the transmission
neutral contact too high.

The transmission neutral
contact is inactive.

Check:
– The transmission neutral contact (S180).
– The MFA (A100) armrest multifunction
module.

Id7521h

MFA (A100)

Voltage of the signal
specified by the transmission
neutral contact too low.

The transmission neutral
contact is inactive.

Check:
– The transmission neutral contact (S180).
– The MFA (A100) armrest multifunction
module.

Id7522h

MFA (A100)

Voltage of the signal
specified by the transmission
neutral contact incoherent.

The transmission neutral
contact is inactive.

Check:
– The transmission neutral contact (S180).
– The MFA (A100) armrest multifunction
module.

Id7523h

MFA (A100)

Voltage of the signal
specified by the 1 engine
speed memory too high
contact.

The engine speed memory 1 is
inactive

Check:
– The engine speed memory 1 contact
(S178).
– The MFA (A100) armrest multifunction
module.

Id7524h

MFA (A100)

Voltage of the signal
specified by the engine
speed memmory 1 too low
contact.

The engine speed memory 1 is
inactive

Check:
– The engine speed memory 1 contact
(S178).
– The MFA (A100) armrest multifunction
module.

Id7525h

MFA (A100)

Voltage of the signal
specified by the engine
speed memory 1 incoherent
contact.

The engine speed memory 1 is
inactive

Check:
– The engine speed memory 1 contact
(S178).
– The MFA (A100) armrest multifunction
module.

Id7526h

MFA (A100)

Voltage of the signal
specified by the 2 engine
speed memory too high
contact.

The engine speed memory 2 is
inactive

Check:
– The engine speed memory 2 contact
(S179).
– The MFA (A100) armrest multifunction
module.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7527h

MFA (A100)

Voltage of the signal
specified by the engine
speed memmory 2 too low
contact.

The engine speed memory 2 is
inactive

Check:
– The engine speed memory 2 contact
(S179).
– The MFA (A100) armrest multifunction
module.

Id7528h

MFA (A100)

Voltage of the signal
specified by the engine
speed memory 2 incoherent
contact.

The engine speed memory 2 is
inactive

Check:
– The engine speed memory 2 contact
(S179).
– The MFA (A100) armrest multifunction
module.

Id7529h

MFA (A100)

Voltage of the signal
specified by the engine
speed + too high contact.

The engine speed + contact is
inactive.

Check:
– The + engine speed contact (S188).
– The MFA (A100) armrest multifunction
module.

Id752Ah

MFA (A100)

Voltage of the signal
specified by the engine
speed + too low contact.

The engine speed + contact is
inactive.

Check:
– The + engine speed contact (S188).
– The MFA (A100) armrest multifunction
module.

Id752Bh

MFA (A100)

Voltage of the signal
specified by the engine
speed + incoherent contact.

The engine speed + contact is
inactive.

Check:
– The + engine speed contact (S188).
– The MFA (A100) armrest multifunction
module.

Id752Ch

MFA (A100)

Voltage of the signal
specified by the engine
speed – too high contact.

The engine speed – contact is
inactive.

Check:
– The – engine speed contact (S189).
– The MFA (A100) armrest multifunction
module.

Id752Dh

MFA (A100)

Voltage of the signal
specified by the engine
speed – too low contact.

The engine speed – contact is
inactive.

Check:
– The – engine speed contact (S189).
– The MFA (A100) armrest multifunction
module.

Id752Eh

MFA (A100)

Voltage of the signal
specified by the engine
speed – incoherent contact.

The engine speed – contact is
inactive.

Check:
– The – engine speed contact (S189).
– The MFA (A100) armrest multifunction
module.

Id752Fh

MFA (A100)

Voltage of the signal
specified by the stop
sequence too high contact.

The Claas Sequence
Management is inactive.

Check:
– The stop sequence contact (S185).
– The MFA (A100) armrest multifunction
module.

Id7530h

MFA (A100)

Voltage of the signal
specified by the stop
sequence too low contact.

The Claas Sequence
Management is inactive.

Check:
– The stop sequence contact (S185).
– The MFA (A100) armrest multifunction
module.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7531h

MFA (A100)

Voltage of the signal
specified by the stop
sequence incoherent
contact.

The Claas Sequence
Management is inactive.

Check:
– The stop sequence contact (S185).
– The MFA (A100) armrest multifunction
module.

Id7532h

MFA (A100)

Voltage of the signal
specified by the sequence 1
too high contact.

The Claas Sequence
Management is inactive.

Check:
– The sequence 1 contact (S186).
– The MFA (A100) armrest multifunction
module.

Id7533h

MFA (A100)

Voltage of the signal
specified by the sequence 1
too low contact.

The Claas Sequence
Management is inactive.

Check:
– The sequence 1 contact (S186).
– The MFA (A100) armrest multifunction
module.

Id7534h

MFA (A100)

Voltage of the signal
specified by the sequence 1
incoherent contact.

The Claas Sequence
Management is inactive.

Check:
– The sequence 1 contact (S186).
– The MFA (A100) armrest multifunction
module.

Id7535h

MFA (A100)

Voltage of the signal
specified by the sequence 2
too high contact.

The Claas Sequence
Management is inactive.

Check:
– The sequence 2 contact (S187).
– The MFA (A100) armrest multifunction
module.

Id7536h

MFA (A100)

Voltage of the signal
specified by the sequence 2
too low contact.

The Claas Sequence
Management is inactive.

Check:
– The sequence 2 contact (S187).
– The MFA (A100) armrest multifunction
module.

Id7537h

MFA (A100)

Voltage of the signal
specified by the sequence 2
incoherent contact.

The Claas Sequence
Management is inactive.

Check:
– The sequence 2 contact (S187).
– The MFA (A100) armrest multifunction
module.

Id7538h

MFA (A100)

Voltage of the signal
specified by the Auto pilot
contact too high.

Autopilot is inactive.

Check:
– The Auto pilot contact.
– The MFA (A100) armrest multifunction
module.

Id7839h

MFA (A100)

Voltage of the signal
specified by the Auto pilot
contact too low.

Autopilot is inactive.

Check:
– The Auto pilot contact.
– The MFA (A100) armrest multifunction
module.

Id753Ah

MFA (A100)

Voltage of the signal
specified by the Auto pilot
contact incoherent.

Autopilot is inactive.

Check:
– The Auto pilot contact.
– The MFA (A100) armrest multifunction
module.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id753Bh

MFA (A100)

Voltage of the signal
specified by the function F1
too high contact.

The function F1 contact is
inactive.

Check:
– The function F1 contact (S190).
– The MFA (A100) armrest multifunction
module.

Id753Ch

MFA (A100)

Voltage of the signal
specified by the function F1
too low contact.

The function F1 contact is
inactive.

Check:
– The function F1 contact (S190).
– The MFA (A100) armrest multifunction
module.

Id753Dh

MFA (A100)

Voltage of the signal
specified by the function F1
incoherent function.

The function F1 contact is
inactive.

Check:
– The function F1 contact (S190).
– The MFA (A100) armrest multifunction
module.

Id753Eh

MFA (A100)

Voltage of the signal
specified by the function F2
too high contact.

The function F2 contact is
inactive.

Check:
– The function F2 contact (S191).
– The MFA (A100) armrest multifunction
module.

Id753Fh

MFA (A100)

Voltage of the signal
specified by the function F2
too low contact.

The function F2 contact is
inactive.

Check:
– The function F2 contact (S191).
– The MFA (A100) armrest multifunction
module.

Id7540h

MFA (A100)

Voltage of the signal
specified by the function F2
incoherent function.

The function F2 contact is
inactive.

Check:
– The function F2 contact (S191).
– The MFA (A100) armrest multifunction
module.

Id7541h

MFA (A100)

Signal voltage returned by
the (+) contact for speed
range shifting too high.

The (+) contact for speed range
shifting is inactive (C-Matic).

Check:
– The (+) contact on speed range shifting
(S200).
– The MFA (A100) armrest multifunction
module.

Id7542h

MFA (A100)

Voltage of the signal sent by
the (+) contact for speed
range shifting too low.

The (+) contact for speed range
shifting is inactive (C-Matic).

Check:
– The (+) contact on speed range shifting
(S200).
– The MFA (A100) armrest multifunction
module.

Id7543h

MFA (A100)

Voltage of the signal sent by
the (+) contact for speed
range shifting incoherent.

The (+) contact for speed range
shifting is inactive (C-Matic).

Check:
– The (+) contact on speed range shifting
(S200).
– The MFA (A100) armrest multifunction
module.

Id7544h

MFA (A100)

Signal voltage returned by
the (-) contact for speed
range shifting too high.

The (+) contact for speed range
shifting is inactive (C-Matic).

Check:
– The (-) contact on speed range shifting
(S201).
– The MFA (A100) armrest multifunction
module.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7545h

MFA (A100)

Voltage of the signal sent by
the (-) contact for speed
range shifting too low.

The (+) contact for speed range
shifting is inactive (C-Matic).

Check:
– The (-) contact on speed range shifting
(S200).
– The MFA (A100) armrest multifunction
module.

Id7546h

MFA (A100)

Voltage of the signal sent by
the (-) contact for speed
range shifting incoherent.

The (+) contact for speed range
shifting is inactive (C-Matic).

Check:
– The (-) contact on speed range shifting
(S201).
– The MFA (A100) armrest multifunction
module.

Id7547h

MFA (A100)

Voltage of the signal
specified by the
manoeuvering gear too high
contact.

The manoeuvering gear
function is inactive.

Check:
– The manoeuvering gear contact (S177).
– The MFA (A100) armrest multifunction
module.

Id7548h

MFA (A100)

Voltage of the signal
specified by the
manoeuvering gear too low
contact.

The manoeuvering gear
function is inactive.

Check:
– The manoeuvering gear contact (S177).
– The MFA (A100) armrest multifunction
module.

Id7549h

MFA (A100)

Voltage of the signal
specified by the
manoeuvering gear
incoherent contact.

The manoeuvering gear
function is inactive.

Check:
– The manoeuvering gear contact (S177).
– The MFA (A100) armrest multifunction
module.

Id754Ah

MFA (A100)

Voltage of the signal
specified by the function F3
too high contact.

The F3 function is inactive.

Check:
– The function F3 contact (S198).
– The MFA (A100) armrest multifunction
module.

Id754Bh

MFA (A100)

Voltage of the signal
specified by the function F3
too low contact.

The F3 function is inactive.

Check:
– The function F3 contact (S198).
– The MFA (A100) armrest multifunction
module.

Id754Ch

MFA (A100)

Voltage of the signal
specified by the function F3
incoherent function.

The F3 function is inactive.

Check:
– The function F3 contact (S198).
– The MFA (A100) armrest multifunction
module.

Id754Dh

MFA (A100)

Voltage of the signal
specified by the function F4
too high contact.

The F4 function is inactive.

Check:
– The function F4 contact (S199).
– The MFA (A100) armrest multifunction
module.

Id754Eh

MFA (A100)

Voltage of the signal
specified by the function F4
too low contact.

The F4 function is inactive.

Check:
– The function F4 contact (S199).
– The MFA (A100) armrest multifunction
module.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id754Fh

MFA (A100)

Voltage of the signal
specified by the function F4
incoherent function.

The F4 function is inactive.

Check:
– The function F4 contact (S199).
– The MFA (A100) armrest multifunction
module.

Id7550h

MFA (A100)

Voltage of the signal
specified by the cross control
locking Electropilot too high
contact.

The Electropilot cross control is
inactive.

Check:
– The Electropilot cross control locking
contact (S183).
– The MFA (A100) armrest multifunction
module.

Id7551h

MFA (A100)

Voltage of the signal
specified by the Electropilot
cross control locking too low
contact.

The Electropilot cross control is
inactive.

Check:
– The Electropilot cross control locking
contact (S183).
– The MFA (A100) armrest multifunction
module.

Id7552h

MFA (A100)

Voltage of the signal
specified by the Electropilot
cross control locking
incoherent contact.

The Electropilot cross control is
inactive.

Check:
– The Electropilot cross control locking
contact (S183).
– The MFA (A100) armrest multifunction
module.

Id7553h

MFA (A100)

Error on
CLAAS vehicle CAN bus.

Random operation of the
multifunction armrest.

Check:
– The CLAAS vehicle CAN bus network.
– The CAN bus network communication
module BDG (A103).
– The TR2 transmission module (A57-2).

Id7554h

MFA (A100)

The multifunction armrest
does not receive the CAN
message for backlighting and
activation lamps.

The backlighting of the
multifunction armrest is
activated by default.

Check:
– The CLAAS vehicle CAN bus network.
– The CAN bus network communication
module BDG (A103).
– The instrument panel module DBD (A101).

Id7555h

MFA (A100)

Error on
CLAAS vehicle CAN bus.

Random operation of the
multifunction armrest.

Check:
– The CLAAS vehicle CAN bus network.
– The CAN bus network communication
module BDG (A103).
– The instrument panel module DBD (A101).

Id7556h

MFA (A100)

The multifunction armrest no
longer emits the message
over the
CLAAS vehicle CAN bus due
to too many CAN error
frames over the
CLAAS vehicle CAN bus.

The multifunction armrest is
inactive.
The current gear is maintained.
After restarting, the gears
available are C1 and B1,
according to the work/transport
mode selected.

Check:
The MFA (A100) armrest multifunction
module.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

TR1 (A57-1)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id75C0h

301

TR1 (A57-1)

Inconsistent current
measurements obtained on
the forward gear solenoid
valve.
A different value is received
from each of the two
measuring points on the
return.
The "Auto 5" working with
the estimated current.

Audio warning:: No.
"ISC" reset requested: No.

Check:
The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id75C1h

302

TR1 (A57-1)

Inconsistent current
measurements obtained on
the reverse gear solenoid
valve.
A different value is received
from each of the two
measuring points on the
return.
The "Auto 5" working with
the estimated current.

Id75C2h

303

TR1 (A57-1)

Supply voltage measured on
the forward gear solenoid
valve when the driver is not
controlled
(setpoint PWM = 0).

Audio warning:: Yes.
"ISC" reset requested: Yes.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id75C3h

304

TR1 (A57-1)

Supply voltage measured on
the reverse gear solenoid
valve when the driver is not
controlled
(setpoint PWM = 0).

Id75C4h

305

TR1 (A57-1)

Actual current measured on
the return of the forward gear
solenoid valve is too high
relative to the setpoint.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The resistance of the solenoid valve
winding.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id75C5h

306

TR1 (A57-1)

Actual current measured on
the return of the reverse gear
solenoid valve is too high
relative to the setpoint.

Id75C6h

307

TR1 (A57-1)

The current consumed by the
forward gear solenoid valve
is greater than 1,4 A
(maximum allowable).

Check:
– The solenoid valve if 301/302 are not
shown.
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The resistance of the solenoid valve
winding.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id75C7h

308

TR1 (A57-1)

The current consumed by the
reverse gear solenoid valve
is greater than 1,4 A
(maximum allowable).

Id75C8h

309

TR1 (A57-1)

The actual current measured
on the forward gear solenoid
valve return is less than the
setpoint value.

Audio warning:: Yes.
"ISC" reset requested: Yes.

Check:
– For a possible open circuit in the solenoid
valve supply harness.
– For a possible short circuit to earth on the
solenoid valve.
– The resistance of the solenoid valve
winding.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id75C9h

310

TR1 (A57-1)

The actual current measured
on the reverse gear solenoid
valve return is less than the
setpoint value.

Id75CAh

311

TR1 (A57-1)

The current sent to the
forward gear solenoid valve
is insufficient (current
regulation problem).

Audio warning:: No.
"ISC" reset requested: No.

Check:
– The battery voltage.
– For a possible resistance on the solenoid
valve supply.
– The solenoid valve winding.

Id75CBh

312

TR1 (A57-1)

The current sent to the
reverse gear solenoid valve
is insufficient (current
regulation problem).

Id75CCh

313

TR1 (A57-1)

Loss of shuttle reverser
output speed information
(knowing that the theoretical
speed is indicated).

Audio warning:: Yes.
"ISC" reset requested: No.

Check:
The reverser exit speed sensor under
torque (B229).

Id75CDh

314

TR1 (A57-1)

Loss of the ENG module
engine speed information
(knowing the units are
supplied with 12V after
ignition and a theoretical
speed of > 1 km/h is
specified).

Check:
The Powertrain CAN bus network.
The engine module (A15).

Id75CEh

315

TR1 (A57-1)

Loss of theoratical speed
information (knowing that the
shuttle reverser output speed
is indicated).
This fault not detected when
changing range or a slow
range is engaged.

Audio warning:: No.
"ISC" reset requested: No.

Check:
The theoretical speed sensor (B227).

Id75CFh

316

TR1 (A57-1)

The voltage of the signal
provided by the clutch pedal
sensor is < 0,3 V or > 4,8 V.

Audio warning:: No.
"ISC" reset requested: Yes.

Check:
The clutch pedal position potentiometer
(R73).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id75D0h

317

TR1 (A57-1)

The voltage of the signal
provided by the accelerator
pedal sensor is < 0,3 V or >
4,8 V.

Audio warning:: No.
"ISC" reset requested: No.
The Hexactiv function is
inactive.
The engine remains in idle
speed.

Check:
The clutch pedal position potentiometer
(R71).

Id75D1h

318

TR1 (A57-1)

Loss of the theoretical
forward speed information on
the Powertrain CAN bus or
inconsistency between the
theoretical forward speed
information on the
Powertrain CAN bus and the
information from the
theoretical forward speed
sensor.

Audio warning:: No.
"ISC" reset requested: No.
The REH (A58) lifting module
and its associated functions
may be lost.

Check:
– The instrument panel module (A101).
– The Powertrain CAN bus network.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id75D2h

319

TR1 (A57-1)

Inconsistency between the
information from the crawler
range engaging contact and
the mechanical status of the
crawler range.

Check:
– The theoretical speed sensor (B227).
– The slow range contact (Z150).
– Status of the crawler range.
– Status of the range module.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id75D4h

321

TR1 (A57-1)

The information provided by
the reverser lever is
inconsistent (several states
simultaneously).

Audio warning:: Yes or no.
"ISC" reset requested: Yes if
sound alarm.

Check:
– The reverser lever (S171).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id75D6h

323

TR1 (A57-1)

The position of the clutch
pedal and the status of the
end-of-travel switch (BOC)
are inconsistent.
There are three possible
cases:
The pedal is fully released
(angle sensor signal) but the
"BOC" is closed (12 V on
terminal pin 30 of the
"Auto 5.51).
The "BOC" indicates that the
pedal is not fully released
(12 V on terminal pin 30 of
the "Auto 5.51) but the
reverser controller is in
neutral (12 V on terminal pin
19 of the "Auto 5.51).
The reverser controller is not
in neutral (zero voltage on
teminal pin 19 of the "Auto
5.51"), the clutch pedal is
depressed more than 50 %
(angle sensor signal) but the
pedal arm sensor remains
open (0 V on teminal pin 30
of the "Auto 5.51").

Audio warning:: Yes or no.
"ISC" reset requested: Yes if
sound alarm.

Check:
– The clutch pedal position potentiometer
(R73).
– The "BOC" clutch pedal low contact (Z152).
– The neutral position of the reverser lever
(S171).
– For a possible short circuit on 12 V on the
harnesses of terminal pins 30 or 19.
– For a possible open circuit on the harness
of terminal pin 30.
– The "Auto 5" module using tool n° 60 05
033 249, and change if required.

Id75D7h

324

TR1 (A57-1)

The status of the engaged
range does not correspond
to the range engaged.

Audio warning:: No.
"ISC" reset requested: Yes if
tractor stopped.

Check:
– The A range engaged contact (Z153-1).
– The B range engaged contact (Z153-2).
– The C range engaged contact (Z153-3).
– The D range engaged contact (Z153-4).
– For a possible mechanical problem on the
range module.

Id75D8h

325

TR1 (A57-1)

A minimum of 2 range
sensors are simultaneously
open (normally only 1).

   

Id75D9h

326

TR1 (A57-1)

The comparison of the
information from the reverser
output speed sensor and the
theoretical speed sensor is
inconsistent.

   

Id75DAh

327

TR1 (A57-1)

Physical error on the CAN
network.
At least one of the tractor
computers is not detected or
CAN network overload.

Audio warning:: Yes.
"ISC" reset requested: Yes.

Check:
The Powertrain CAN bus network.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id75DBh

328

TR1 (A57-1)

Unable to read tractor
specific parameters in
EEPROM memory.

Audio warning:: No.
"ISC" reset requested: No.

Configure the "Auto 5" modules using
Win Metadiag© otherwise change the
"Auto 5".

Id75DCh

329

TR1 (A57-1)

Problem saving parameters
when placing units on
standby.

Check:
For a possible loss of the permanent 12 V
supply prior to 12 V shutoff after switching
on the ignition, otherwise change the
"Auto 5".

Id75DDh

330

TR1 (A57-1)

The unit 12 V supply voltage
is less than 7 V after
switching on the ignition.

Check:
– The battery voltage.
– The 12V harnesses and connections after
contact of the "Auto 5" modules.

Id75DEh

331

TR1 (A57-1)

The 10 V supply to the
sensors is not within the
± 5 % tolerance.

Check:
– For a possible short circuit (harnesses or
sensors).
– The harnesses and their connections.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id75DFh

332

TR1 (A57-1)

Short circuit or open circuit
on range A solenoid valve
(SVA).

Audio warning:: Yes.
"ISC" reset requested: No.

Check:
– Solenoid valve of (SVA) (Y339-1) robotized
range.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id75E0h

333

TR1 (A57-1)

Short circuit or open circuit
on range B solenoid valve
(SVB).

Check:
– Solenoid valve of (SVB) (Y339-2) robotized
range.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Id75E1h

334

TR1 (A57-1)

Short circuit or open circuit
on range C solenoid valve
(SVC).

Check:
– Solenoid valve of (SVC) (Y339-3) robotized
range.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Id75E2h

335

TR1 (A57-1)

Short circuit or open circuit
on range D solenoid valve
(SVD).

Check:
– Solenoid valve of (SVD) (Y339-4) robotized
range.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Id75E3h

336

TR1 (A57-1)

Inconsistant "Auto 5" analog
readings.

Audio warning:: No.
"ISC" reset requested: No.

Check:
– For a possible short circuit between the
accelerator sensor harness and range
sensor A, B.
– For a possible short circuit between the
clutch sensor harness and C, D range
sensor.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id75E4h

337

TR1 (A57-1)

Inconsistency between the
selected gear and the
measured ratio.

Audio warning:: Yes.
"ISC" reset requested: Yes.
The Powershift 4 gear is
reached gradually by default.

Check:
– Engine speed data.
– The reverser exit speed sensor under
torque (B229).
– For a possible seizure of the forward/
reverse or "Hexashift solenoid valves
(PSV1, PSV2, PSV3).
– For a possible mechanical problem on the
forward/reverse or "Hexashift" clutches
(slippage).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id75F5h

354

TR1 (A57-1)

Short circuit on range A
sensor.

Audio warning:: No.
"ISC" reset requested: No.

Check:
– The A range engaged contact (Z153-1).
– The B range engaged contact (Z153-2).
– The C range engaged contact (Z153-3).
– The D range engaged contact (Z153-4).
– Warning: During voltage control as the
"Auto 5" fuse is burnt out.

Id75F6h

355

TR1 (A57-1)

Short circuit on range B
sensor.

   

Id75F7h

356

TR1 (A57-1)

Short circuit on range C
sensor.

   

Id75F8h

357

TR1 (A57-1)

Short circuit on range D
sensor.

   

Id75F9h

358

TR1 (A57-1)

Calibration of the Revershift
ongoing.

 

Id75FAh

359

TR1 (A57-1)

Stack overload.

 

Id75FBh

360

TR1 (A57-1)

Paddle in forward gear (or
reverse) and paddle up at the
same time.

Audio warning:: Yes or no.
"ISC" reset requested: Yes if
sound alarm.

Check:
– The reverser lever (S171).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id75FCh

361

TR1 (A57-1)

Paddle in forward gear (or
reverse) and paddle in
neutral at the same time.

   

Id75FDh

362

TR1 (A57-1)

Paddle in forward gear and
reverse at the same time.

   

Id75FEh

363

TR1 (A57-1)

Palette position not detected.

   

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

TR2 (A57-2)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id7620h

401

TR2 (A57-2)

Pressure of high-pressure
brakes < 70 bar at
initialisation.

Audio warning:: Yes.
Brake indicator light: Steady
"on".

Check:
– The hydraulic circuit (valve, pipes,
switch...).
– Braking pressure sensor (B233).
– High pressure braking solenoid valve
(Y329).
– Voltage delivered by the transformer (V24).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7621h

402

TR2 (A57-2)

Pressure of high-pressure
brakes < 70 bar during < 2
seconds, during operation.

   

Id7622h

403

TR2 (A57-2)

Pressure of high-pressure
brakes does not drop, or too
high.

Audio warning:: No.
Brake indicator light: BLINKING.

Check:
– The hydraulic circuit (valve, pipes,
switch...).
– Braking pressure sensor (B233).
– High pressure braking solenoid valve
(Y329).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7623h

404

TR2 (A57-2)

Supply problem with high
pressure brake sensor.

Audio warning:: Yes.
Brake indicator light: Steady
"on".

Check:
– Voltage delivered by the transformer (V24).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7624h

405

TR2 (A57-2)

78 bar < pressure of high
pressure brakes < 98 bar at
initialisation.
Instead of 98 bar < pressure
of high-pressure brakes <
120 bar.
The pressure value filled in
by the sensor is greater than
around 2 to 4 bar of the real
pressure in the cicuit.

Audio warning:: No.
Brake indicator light: BLINKING.

Check:
– The hydraulic circuit (valve, pipes,
switch...).
– Braking pressure sensor (B233).
– High pressure braking solenoid valve
(Y329).
– Voltage delivered by the transformer (V24).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7625h

406

TR2 (A57-2)

High-pressure brake
accumulator inflates too
often (leak on energy
reserve).

Check:
The hydraulic circuit (valve, pipes,
switch...).

 

 

Id7626h

407

TR2 (A57-2)

High-pressure brake sensor
disconnected.

Audio warning:: Yes.
Brake indicator light: Steady
"on".

Check:
– Braking pressure sensor (B233).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7627h

408

TR2 (A57-2)

High-pressure brake
accumulator faulty, torn.

Check:
Cumulator (5016).

 

Id7628h

409

TR2 (A57-2)

Loss of the Hexactiv function
engaged on the
Powertrain CAN bus
information or Hexactiv
function engaged information
exceeds 10 seconds.

Audio warning:: No.
"ISC" reset requested: Yes.
The Hexactiv function is
inactive.

Check:
– Hexactiv engaged function contact (S192).
– The Armrest (A30) module.
– The Powertrain CAN bus network.
– The CLAAS vehicle CAN bus network.
– The Bridge (A103) module.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7629h

410

TR2 (A57-2)

Full left steering position not
validated when configuring
the steering angle sensor
(B117).

Return to normal mode by
pressing the differential lock
button.

Turn the wheels fully to the left. Validate
by pressing the differential locking button.
Do not forget to validate the wheel in line
position of the steering.

Id762Ah

411

TR2 (A57-2)

Wheel in line position not
validated when configuring
the steering angle sensor
(B117).

Return to normal mode by
pressing the differential lock
button.

Set the wheels straight. Validate by
pressing the differential locking button. Do
not forget to validate the right-hand
mechanical stop position of the steering.

Id762Bh

412

TR2 (A57-2)

Steering right-hand
mechanical stop position not
validated when configuring
the steering angle sensor
(B117)

Return to normal mode by
pressing the differential lock
button.

Turn the wheels fully to the right. Validate
by pressing the differential locking button.
Do not forget to validate the right-hand
steering mechanical stop position to finish
calibration.

Id762Ch

413

TR2 (A57-2)

Voltage of the steering angle
sensor (B117) outside 0,5V
and 4,5V. The transmission
module TR2 (A57-2)
considers that the steering
angle is 0°

Diagnostic lamp blinks.
Check:
The steering angle sensor (B117) and the
wiring between sensor and module.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id762Dh

414

TR2 (A57-2)

Loss of the ENG module
engine speed information
(knowing the units are
supplied with 12V after
ignition and a theoretical
speed of > 1 km/h is
specified).

Audio warning:: Yes.
"ISC" reset requested: No.

Check:
The Powertrain CAN bus network.
The engine module ENG (A15).

Id762Eh

415

TR2 (A57-2)

Loss of the theoretical
forward speed on the
Powertrain CAN bus
information although the
gearbox intermediate speed
information (on Revershift
output) is present on
Powertrain CAN bus.

Audio warning:: Yes.
"ISC" reset requested: No.

Check:
– The instrument panel module DBD (A101).
– Status of the crawler range.
– Status of the range module.
– The Powertrain CAN bus network.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id762Fh

416

TR2 (A57-2)

Error on high pressure
braking.

Pressure < 70 bar during
initialization. The tractor is
limited to gear B6.
Engine
speed 300 rpm.

Pump for 15 seconds. Start the tractor.

Id7630h

417

TR2 (A57-2)

Error on high pressure
braking.

Pressure < 70 bar at least 2
seconds during operation. The
tractor is limited to gear B6.
Engine speed 300 rpm.

Pump for 15 seconds. Start the tractor.

Id7631h

418

TR2 (A57-2)

Loss of gear upshift control
information on the
Powertrain CAN bus.

Audio warning:: Yes.
"ISC" reset requested: No.
Return to the default start gear
after shifting to transmission
neutral.

Check:
– the Drivestick (R74).
– The Armrest (A30) module.
– The Powertrain CAN bus network.
– The CLAAS vehicle CAN bus network.
– The Bridge (A103) module.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7632h

419

TR2 (A57-2)

Loss of the downshifting
control on
Powertrain CAN bus
information.

   

Id7633h

420

TR2 (A57-2)

Loss of the up and down
shifting control of ranges on
Powertrain CAN bus
information.

   

Id7634h

421

TR2 (A57-2)

Error on high pressure
braking.

Pressure exceeds the
maximum threshold during
initialization. Engine speed is
limited at 300 rev/min.

Pump for 15 seconds. Start the tractor.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7635h

422

TR2 (A57-2)

The transmission oil
temperature provided by the
temperature sensor is <
24 °C or > 150 °C.

Audio warning:: Yes.
"ISC" reset requested: No.

Check:
– The transmission oil temeprature sensor
(B123).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7636h

423

TR2 (A57-2)

Error on high pressure
braking.

Pressure ranges between 78
and 98 bars during initialization.
Engine speed is limited at 300
rev/min.

Pump for 15 seconds. Start the tractor.

Id7637h

424

TR2 (A57-2)

Error on high pressure
braking.

The accumulator inflates too
often (risk of leaks).

Cancel the fault, If the error appears
again, Restart the tractor.

Id7638h

425

TR2 (A57-2)

Error on high pressure
braking.

The pressure sensor (B233) is
disconnected

Pump for 15 seconds. Start the tractor.

Id7639h

426

TR2 (A57-2)

Error on high pressure
braking.

Pressure < 70 bars during 0,2 to
2 seconds.

Pump for 15 seconds. Start the tractor.

Id763Ah

427

TR2 (A057-2)

Physical error on the CAN
network.
At least one of the tractor
computers is not detected or
CAN network overload.

Audio warning:: Yes.
"ISC" reset requested: Yes.

Check:
The Powertrain CAN bus network.

Id763Bh

428

TR2 (A57-2)

Unable to read tractor
specific parameters in
EEPROM memory.

Audio warning:: No.
"ISC" reset requested: No.

Configure the "Auto 5" modules using
Win Metadiag© otherwise change the
"Auto 5".

Id763Ch

429

TR2 (A57-2)

Problem saving parameters
when placing units on
standby.

Check:
For a possible loss of the permanent 12 V
supply prior to 12 V shutoff after switching
on the ignition, otherwise change the
"Auto 5".

 

Id763Dh

430

TR2 (A57-2)

The unit 12 V supply voltage
is less than 7 V after
switching on the ignition.

Check:
– The battery voltage.
– The 12V harnesses and connections after
contact of the "Auto 5" modules.

 

Id763Eh

431

TR2 (A57-2)

The 10 V supply to the
sensors is not within the ±
5 % tolerance.

Check:
– For a possible short circuit (harnesses or
sensors).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7640h

433

TR2 (A57-2)

Calibration of the Power
Boost failed, Power Boost
only in C and D

Bad measurement. Engine
speed sensor 1 of 2
disconnected

Recalibrate

Id7641h

434

TR2 (A57-2)

During operation Powerboost
only in C and D

Engine speed sensor 1 of 2
disconnected

Bad measurement. The tractor returns to
normal mode once the fault disappears

Id7643h

436

TR2 (A57-2)

Inconsistant "Auto 5" analog
readings.

Audio warning:: No.
"ISC" reset requested: No.

Check:
– For a possible short circuit between the
accelerator sensor harness and range
sensor A, B (S1, S2).
– For a possible short circuit between the
clutch sensor harness and C, D (S3, S4)
range sensor.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7645h

438

TR2 (A57-2)

Supply voltage measured on
solenoid valve SV3 when the
driver is not controlled
(setpoint PWM = 0).

Audio warning:: Yes.
"ISC" reset requested: Yes.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7646h

439

TR2 (A57-2)

Actual current measured on
the return of solenoid valve
SV3 is too high relative to the
setpoint.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The solenoid valve SV3 (Y335-3)
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Id7647h

440

TR2 (A57-2)

The current consumed by
solenoid valve SV3 is greater
than 1,4 A (maximum
allowable).

Audio warning:: Yes.
"ISC" reset requested: Yes.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The solenoid valve SV3 (Y335-3)
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7648h

441

TR2 (A57-2)

The actual current measured
on the solenoid valve SV3
return is less than the
setpoint value.

Check:
– For a possible open circuit in the solenoid
valve supply harness.
– For a possible short circuit to earth on the
solenoid valve.
– The solenoid valve SV3 (Y335-3)
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7649h

442

TR2 (A57-2)

The current sent to solenoid
valve SV3 is insufficient
(current regulation problem).

Audio warning:: Yes.
"ISC" reset requested: Yes.

Check:
– The battery voltage.
– For a possible resistance on the solenoid
valve supply.
– The solenoid valve SV3 (Y335-3)

Id764Ah

443

TR2 (A57-2)

Supply voltage measured on
solenoid valve SV2 when the
driver is not controlled
(setpoint PWM = 0).

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Id764Bh

444

TR2 (A57-2)

Actual current measured on
the return of solenoid valve
SV2 is too high relative to the
setpoint.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The solenoid valve SV2 (Y335-2)
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Id764Ch

445

TR2 (A57-2)

The current consumed by
solenoid valve SV2 is greater
than 1,4 A (maximum
allowable).

Audio warning:: Yes.
"ISC" reset requested: Yes.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The solenoid valve SV2 (Y335-2)
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id764Dh

446

TR2 (A57-2)

The actual current measured
on the solenoid valve SV2
return is less than the
setpoint value.

Check:
– For a possible open circuit in the solenoid
valve supply harness.
– For a possible short circuit to earth on the
solenoid valve.
– The solenoid valve SV2 (Y335-2)
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Id764Eh

447

TR2 (A57-2)

The current sent to solenoid
valve SV2 is insufficient
(current regulation problem).

Audio warning:: Yes.
"ISC" reset requested: Yes.

Check:
– The battery voltage.
– For a possible resistance on the solenoid
valve supply.
– The solenoid valve SV2 (Y335-2).

Id764Fh

448

TR2 (A57-2)

Supply voltage measured on
solenoid valve SV1 when the
driver is not controlled
(setpoint PWM = 0).

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7650h

449

TR2 (A57-2)

Actual current measured on
the return of solenoid valve
SV1 is too high relative to the
setpoint.

Audio warning:: Yes.
"ISC" reset requested: Yes.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The solenoid valve SV1 (Y335-1)
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7651h

450

TR2 (A57-2)

The current consumed by
solenoid valve SV1 is greater
than 1,4 A (maximum
allowable).

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The solenoid valve SV1 (Y335-1)
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Id7652h

451

TR2 (A57-2)

The actual current measured
on the solenoid valve SV1
return is less than the
setpoint value.

Check:
– For a possible open circuit in the solenoid
valve supply harness.
– For a possible short circuit to earth on the
solenoid valve.
– The solenoid valve SV1 (Y335-1)
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Id7653h

452

TR2 (A57-2)

The current sent to solenoid
valve SV1 is insufficient
(current regulation problem).

Check:
– The battery voltage.
– For a possible resistance on the solenoid
valve supply.
– The solenoid valve SV1 (Y335-1)

 

Id7654h

453

TR2 (A57-2)

No 20 bar low pressure
information (knowing that
engine speed > 500 rpm).

Audio warning:: Yes.
"ISC" reset requested: No.

Check:
– The pressure of the low pressure circuit.
– The low pressure sensor (Z154).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7655h

454

TR2 (A57-2)

Calibration of the
Power Boost ongoing.

Id7656h

455

TR2 (A57-2)

Calibration of the right
position of the current
steering angle.

   

Id7657h

456

TR2 (A57-2)

Calibration of the center
position of the current
steering angle.

   

Id7658h

457

TR2 (A57-2)

Calibration of the left position
of the current steering angle.

   

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7659h

458

TR2 (A57-2)

Loss of the information on
"Manoeuvering gear"
function engaged on the
Powertrain CAN bus or
information on
"Manoeuvering gear"
function engaged exceeds
10 seconds or in short
circuit.

The manoeuvering gear
function is inactive.

Check:
– The contact of engaging (S177)
manoeuvering gear.
– The Armrest (A30) module.
– The Powertrain CAN bus network.
– The CLAAS vehicle CAN bus network.
– The (A103) module.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id765Ah

459

TR2 (A57-2)

Stack overload- Random
behaviour.

Random operation.

Id765Bh

460

TR2 (A57-2)

Limitation of the
Claas Power Management
caused by power
consumption on the rear
PTO (540 or 540 Eco)
exceeding transmissible
power.

The Claas Power Management
restricts additional power.

Check:
– Abnormal use of the rear PTO.
– Status of the PTO line.
– Tool coupled.

Id765Ch

461

TR2 (A57-2)

Limitation of the
Claas Power Management
caused by the coolant
temperature too high 105 °C
< T° < 113 °C.

The Claas Power Management
restricts additional power.

Check:
– The engine cooling circuit.
– The engine coolant temperature sensor
(B045).

Id765Dh

462

TR2 (A57-2)

Claas Power Management
function faulty due to loss of
information from engine
speed sensor (on PTO clutch
housing) or engine speed
sensor (on gearbox primary
shaft).

The Claas Power Management
is available in C and D ranges
only.

Check:
– Adjustment of the 2 engine speed sensors
(B228-1, B228-2).
– The engine speed sensor (on PTO clutch
housing) (B228-1).
– The engine speed sensor (on gearbox
primary shaft) (B228-2).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id765Eh

463

TR2 (A57-2)

Claas Power Management
function faulty due to loss of
engine speed information on
the Powertrain CAN bus.

The lowest power curve is
selected by default.

Check:
– The engine module (A15).
– The Powertrain CAN bus network.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id78B0h

840

TR2 (A57-2)

Tranmission module TR2
(A57-2) has detected
communication loss with the
external function module
EXT (A62) during a CSM
sequence

Gear selection command
disconnected

Check:
– The TR2 transmission module (A57-2)
– The external function module EXT (A62)

Id78B1h

841

TR2 (A57-2)

The gearbox is disconnected
during a sequence CSM.

Sequence stopped.

Wait for the sequence to be relaunched.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id78B2h

842

TR2 (A57-2)

Tranmission module TR2
(A57-2) has detected
communication loss with the
external function module
EXT (A62) during a CSM
sequence

DrivestickDisconnected

Check:
– The TR2 transmission module (A57-2)
– The external function module EXT (A62)

Id78B3h

843

TR2 (A57-2)

Field end maneuvering gear
disconnected during a
sequence CSM.

Sequence stopped.

Wait for the sequence to be relaunched.

Id78B4h

844

TR2 (A57-2)

Tranmission module TR2
(A57-2) has detected
communication loss with the
external function module
EXT (A62) during a CSM
sequence

Automatic gear shifting
disconnected

Check:
– The TR2 transmission module (A57-2)
– The external function module EXT (A62)

Id78B5h

845

TR2 (A57-2)

Automatic gear shifting
disconnected during a
sequence CSM.

Sequence stopped.

Wait for the sequence to be relaunched.

Id78B6h

846

TR2 (A57-2)

Tranmission module TR2
(A57-2) has detected
communication loss with the
external function module
EXT (A62) during a CSM
sequence

4 wheel drive disconnected

Check:
– The TR2 transmission module (A57-2)
– The external function module EXT (A62)

Id78B7h

847

TR2 (A57-2)

Tranmission module TR2
(A57-2) has detected
communication loss with the
external function module
EXT (A62) during a CSM
sequence

Differential lock disconnected

Check:
– The TR2 transmission module (A57-2)
– The external function module EXT (A62)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

TR3 (A57-3)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id7680h

501

TR3 (A57-3)

PTO clutch skidding high.

The PTO is off.

Check:
– The rear PTO speed sensor (B142).
– The engine speed sensor (B228-1).
– The pressure of the low pressure circuit.
– Power take-off clutch.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7681h

502

TR3 (A57-3)

Open circuit on the rear PTO
solenoid valve.

The PTO is off.

Check:
– For a possible open circuit in the solenoid
valve supply harness.
– The rear PTO solenoid valve (Y325).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7682h

503

TR3 (A57-3)

Short-circuit to 12V of the
rear PTO solenoid valve.

The PTO is off.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7683h

504

TR3 (A57-3)

Short-circuit to ground of the
rear PTO solenoid valve.

The PTO is off.

Check:
– For a possible open circuit in the solenoid
valve supply harness.
– For a possible short circuit to earth on the
solenoid valve.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7684h

505

TR3 (A57-3)

Drop in engine speed (during
power take-off start-up).

The PTO is off.

Check:
– Possible mechanical problem with the
power take-off.
– Possible problem with the tool driven by the
power take-off.

Id7685h

506

TR3 (A57-3)

Overspeed in economy.

The PTO is off.

Check:
– The rear PTO speed sensor (B142).
– The engine speed sensor (B228-1).
– The engine speed.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7686h

507

TR3 (A57-3)

Battery fault out of range (10
volts - 16 volts).

The PTO is off.

Check:
– The battery.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

 

Id7687h

508

TR3 (A57-3)

The information on the
Powertrain CAN bus indicate
a major drop in engine speed
and a steering pressure
below 9 bar for 4 seconds.

The PTO is off.

Check:
– The steering pressure sensor (Z154).
– The steering pressure.
– The Powertrain CAN bus network.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7688h

509

TR3 (A57-3)

Eegine speed information on
the Powertrain CAN bus
(from the TR2) incoherent.

The PTO is off.

Check:
– The rear PTO speed sensor (B142).
– The rear PTO clutch.
– The engine speed.
– The Powertrain CAN bus network.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7689h

510

TR3 (A57-3)

Clutch time of the PTO too
high.

The PTO continues running in
poor conditions.

Check:
– The rear PTO speed sensor (B142).
– The rear PTO clutch.
– The rear PTO solenoid valve (Y325).
– The steering pressure.
– The engine speed.
– The Powertrain CAN bus network.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id768Ah

511

TR3 (A57-3)

Loss of information from the
rear PTO sensor.

The PTO continues running in
poor conditions.
The PTO is clutched with a
default progressivity.

Check:
– The rear PTO speed sensor (B142).
– Sensor adjustment (B142).
– The rear PTO clutch.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id768Bh

512

TR3 (A57-3)

Regulation of the PTO's
progressivity is not operating
optimally.

The PTO continues running in
poor conditions.

Check:
– The rear PTO speed sensor (B142).
– The engine speed.
– The Powertrain CAN bus network.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id768Ch

513

TR3 (A57-3)

Operating code (no
anomaly).
PTO external engaging
controls (ON/OFF) ON for <
6 seconds (slow PTO
rotation).

Normal operation.

Id768Dh

514

TR3 (A57-3)

Operating code (no
anomaly).
PTO exernal engaging
controls (ON/OFF) used in
OFF.

Normal operation.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id768Eh

515

TR3 (A57-3)

Confirmation of the
automatic power take-off
setting (PTO).

Id768Fh

516

TR3 (A57-3)

Open circuit of automatic
hand brake sensor
disengaged.

The automatic hand brake is
inactive.
Cannot engage or disengage
the automatic hand brake.
Use the release screw to
disengage the automatic hand
brake.

Check:
– Possible open circuit in the harness of
sensor (Z158).
– The sensor (Z158).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7690h

517

TR3 (A57-3)

The automatic hand brake
disengaged sensor is locked
in the engaged position.

The automatic hand brake is
inactive.
Cannot engage or disengage
the automatic hand brake.
Use the release screw to
disengage the automatic hand
brake.

Check:
– Possible open circuit in the harness of
sensor (Z158).
– The automatic hand brake engaged sensor
(Z158).
– Possible mechanical problem on the
automatic hand brake.
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7691h

518

TR3 (A57-3)

Open circuit on the automatic
hand brake disengaging
solenoid valve.

Cannot disengage the
automatic hand brake.
Use the release screw to
disengage the automatic hand
brake.

Check:
– For a possible open circuit in the solenoid
valve supply harness (Y324).
– The resistance of the solenoid valve
winding (Y324).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7692h

519

TR3 (A57-3)

Short-circuit to ground of the
automatic hand brake
disengaging solenoid valve.

Cannot disengage the
automatic hand brake.
Use the release screw to
disengage the automatic hand
brake.

Check:
– For a possible open circuit in the solenoid
valve supply harness (Y324).
– For a possible short circuit to earth on the
solenoid valve (Y324).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7693h

520

TR3 (A57-3)

Information of the automatic
hand brake disengaging
contact in engaged position.

Automatic hand brake contact
inactive.
Use the reverser lever to
disengage the automatic hand
brake.

Check:
– Possible short-circuit in the harness of the
contact (S196).
– The button (S196).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id7694h

521

TR3 (A57-3)

Short-circuit to ground of the
automatic hand brake
engaging solenoid valve.

Cannot engage the automatic
hand brake.

Check:
– For a possible open circuit in the solenoid
valve supply harness (Y323).
– For a possible short circuit to earth on the
solenoid valve (Y323).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7695h

522

TR3 (A57-3)

Open circuit on the automatic
hand brake engaging
solenoid valve.

Cannot engage the automatic
hand brake.

Check:
– For a possible open circuit in the solenoid
valve supply harness (Y323).
– The resistance of the solenoid valve
winding (Y323).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7696h

523

TR3 (A57-3)

Short-circuit to 12V of the
automatic hand brake
disengaging solenoid valve

Cannot engage the automatic
hand brake.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness
(Y324).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7697h

524

TR3 (A57-3)

Short-circuit at 12V of the
automatic hand brake
engaging solenoid valve.

Normal operation.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness
(Y323).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7698h

525

TR3 (A57-3)

Wear sensor of the automatic
hand brake activated.

Wear of the automatic hand
brake.

Check:
– Hand brake wear.
– Otherswise check:
– Possible short-circuit on the sensor harness
(Z157).
– The automatic hand brake wear sensor
(Z157).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id7699h

526

TR3 (A57-3)

Automatic hand brake wear
sensor blocked in active
mode.

The automatic hand brake wear
information is no longer
available.

Check:
– Possible short-circuit on the sensor harness
(Z157).
– The automatic hand brake wear sensor
(Z157).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id769Ah

527

TR3 (A57-3)

Open circuit on the front PTO
engaging solenoid valve.

The front PTO is stopped.

Check:
– For a possible open circuit in the solenoid
valve supply harness (Y326).
– The resistance of the solenoid valve
winding (Y326).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id769Bh

528

TR3 (A57-3)

Short-circuit at the 12V of the
front PTO engaging solenoid
valve.

The front PTO is stopped.

Check:
– For a possible 12 V short circuit on the
solenoid valve power supply harness
(Y326).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id769Ch

529

TR3 (A57-3)

Short-circuit to ground of the
front PTO engaging solenoid
valve.

The front PTO is stopped.

Check:
– For a possible open circuit in the solenoid
valve supply harness (Y326).
– For a possible short circuit to earth on the
solenoid valve (Y323).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id769Dh

530

TR3 (A57-3)

Short-circuit at the 12V of the
rear PTO brake contact.

Rear PTO brake inactive.

Check:
– Possible short-circuit at the 12V in the
harness of the contact (S173).
– The rear PTO brake contact (S173).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id769Eh

531

TR3 (A57-3)

Short-circuit at the 12V of the
automatic rear PTO
engaging contact.

Rear PTO automation inactive.

Check:
– Possible short-circuit at the 12V in the
harness of the contact (S172).
– The rear PTO brake contact (S172).
– The "Auto 5" module using tool n°
60 05 033 249, and change if required.

Id769Fh

532

TR3 (A57-3)

This code appears upon
ignition off after Park-Lock
codes. Check the previous
codes. Automatic handbrake
invalid. The transmission
module TR3 (A57-3) does
not see the key's status
change and switches to
standby.

Problem Park-Lock.
Turn off the main switch, wait
for at least 30 seconds and
restart the engine.
Engage Park
Lock.

The Park-Lock is inoperative.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id78BAh

850

TR3 (A57-3)

Rear power take-off
disconnected during a
sequence CSM.

The power take-off is
inoperative.

After 20 seconds, the tractor initializes,
then the sequence is relaunched.
If nothing happens, reset the CSM.

Id78BBh

851

TR3 (A57-3)

Tranmission module TR3
(A57-3) has detected
communication loss with the
external function module
EXT (A62) during a CSM
sequence.

Rear power take-off
disconnected.

Check:
– The TR3 transmission module (A57-3).
– The external function module EXT (A62).

Id78BCh

852

TR3 (A57-3)

Front power take-off
disconnected during a
sequence CSM.

The power take-off is
inoperative.

After 20 seconds, the tractor initializes,
then the sequence is relaunched.
If nothing happens, reset the CSM.

Id78BDh

853

TR3 (A57-3)

Tranmission module TR3
(A57-3) has detected
communication loss with the
external function module
EXT (A62) during a CSM
sequence.

Front power take-off
disconnected.

Check:
– The TR3 transmission module (A57-3).
– The external function module EXT (A62).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

REH (A58)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id76A0h

711

REH (A58)

Open circuit on the supply of
the lifting solenoid valve.

Lifting is inactive.

Check:
– The rear lifting solenoid valve (Y336).
– The lifting module REH (A58).

Id76A1h

712

REH (A58)

Open circuit on the supply of
the down solenoid valve

Lifting is inactive.

Check:
– The rear down/up solenoid valve (Y337).
– The lifting module REH (A58).

Id76A2h

713

REH (A58)

Short-circuit at 12V or to
ground on power supply of
the up or down solenoid
valve.

Lifting is inactive.

Check:
– The rear lifting solenoid valve (Y336).
– The rear down/up solenoid valve (Y337).
– The lifting module REH (A58).

Id76A3h

714

REH (A58)

Voltage of the external lifting
controls signal non valid.

Lifting is inactive.

Check:
– External controls (S181, S182).
– The lifting module REH (A58).

Id76A5h

716

REH (A58)

12V supply of the REH
module or 10V regulated
voltage non valid.

Lifting is inactive.

Check:
The lifting module REH (A58).

Id76A7h

718

REH (A58)

The REH (A58) lifting module
does not receive any engine
running information on the
Powertrain CAN bus or this
information is in error on the
Powertrain CAN bus, and the
alternator's D+ load signal of
is missing.

Lifting is inactive.

Check:
– The Powertrain CAN bus network.
– The TR2 transmission module (A57-2).
– The engine module ENG (A15).
– The lifting module REH (A58).

Id76ABh

722

REH (A58)

Voltage of the signal of
position sensor non valid.

Lifting is locked. Use external
controls.

Check:
– The position sensor (B139-2).
– The lifting module REH (A58).

 

 

Id76ACh

723

REH (A58)

The REH (A58) lifting module
receives no lifting position
instruction information or this
information is in error on the
Powertrain CAN bus.

Lifting is locked. Use external
controls.

Check:
– The Powertrain CAN bus network.
– The CLAAS vehicle CAN bus network.
– The lifting position instruction potentiometer
(R77).
– The MFA (A100) armrest multifunction
module.
– The lifting module REH (A58).

Id76ADh

724

REH (A58)

Voltage of the high stop
instruction signal non valid.

Lifting is locked. Use external
controls.

Check:
– The lifting control panel (V22).
– The lifting module REH (A58).

Id76B1h

728

REH (A58)

Error on the rear lifting mode
selector.

Rear lifting is blocked.

Restart the tractor.
The external controls located on the
fenders can be used.

Id76B2h

729

REH (A58)

The stop lifting contact of the
multifunction armrest
remained pressed for more
than 6 seconds.

Lifting is locked. Use external
controls.

Check:
– The rear stop lifting contact (S184).
– The MFA (A100) armrest multifunction
module.

Id76B4h

731

REH (A58)

Signal voltage of the right
load sensor non valid.

Load control and transport
damper are inactive.

Check:
– The right load sensor (B144-2).
– The lifting module REH (A58).

Id76B5h

732

REH (A58)

Signal voltage of the left load
sensor non valid.

Load control and transport
damper are inactive.

Check:
– The left load sensor (B144-1).
– The lifting module REH (A58).

Id76B6h

733

REH (A58)

Voltage of the transport
damper control non valid.

Load control and transport
damper are inactive.

Check:
– The lifting control panel (V22).
– The lifting module REH (A58).

Id76B7h

734

REH (A58)

Voltage of the down speed
instruction non valid.

Control of the down speed
inactive. The lowest down
speed is selected by defaut.

Check:
– The lifting control panel (V22).
– The lifting module REH (A58).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id76B8h

735

REH (A58)

The REH lifting module has
not received the theoretical
speed information for more
than 1 second over the
Powertrain CAN bus.

Load control and skid control
are inactive (the load value
considered is the last value
measured).

Check:
– The Powertrain CAN bus network.
– The instrument panel module DBD (A101).
– The lifting module REH (A58).

Id76B9h

736

REH (A58)

Voltage of the load control
instruction signal non valid.

Load control is inactive.

Check:
– The lifting control panel (V22).
– The lifting module REH (A58).

Id76BAh

737

REH (A58)

Voltage of the skid instruction
signal non valid.

Skid control is inactive.

Check:
– The lifting control panel (V22).
– The lifting module REH (A58).

Id76BBh

738

REH (A58)

The REH lifting module has
not received the actual
speed information for more
than 1 second over the
Powertrain CAN bus.

Skid control is inactive (or
deactivated if it was active).

Check:
– The Powertrain CAN bus network.
– The instrument panel module DBD (A101).
– The actual forward speed sensor (radar)
(B230).
– The lifting module REH (A58).

Id76BCh

739

REH (A58)

The REH (A58) lifting module
does not receive the lifting up
mode selection information,
or this information is in error
on the Powertrain CAN bus.

The lifting up mode is inactive.

Check:
– The Powertrain CAN bus network.
– The CLAAS vehicle CAN bus network.
– The actual forward speed sensor (radar)
(B230).
– The lifting module REH (A58).

Id76BEh

741

REH (A58)

The right load sensor is in
overload.

The right load sensor is ignored.

Check:
– A possible mechanical prestress (use non
compliant with lifting).
– The right load sensor (B144-2).
– The lifting module REH (A58).

Id76C0h

743

REH (A58)

Calibrating....

Lifting calibration....

None.

Id76C1h

744

REH (A58)

Lifting parameters have been
reinitialized (factory
parameters).

The lifting parameters have
been reinitialized (factory
parameters) following a
problem during lifting
calibration.

Check:
The lifting module REH (A58).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id78CFh

871

REH (A58)

Rear lifting disconnected
during a sequence CSM.

Rear lifting is inoperative.

After 20 seconds, the tractor initializes,
then the sequence is relaunched.
If nothing happens, reset the CSM.

Id78D0h

872

REH (A58)

The lifting module REH (A58)
detects communication loss
with the external function
module EXT (A62) during a
CSM sequence.

Rear lifting disconnected.

Check:
– The lifting module REH (A58)
– The external function module EXT (A62).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

SFA (A102)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id7580h

900

SFA (A102)

The cab suspension
compressor is inoperative.

The compressor (Y334) is
inoperative 100 ms after the
command of the SFA (A102).

Check the supply voltage of the
compressor between the 1 (+AVC) and 3
(ground) terminals and the command
between the 2 (command) and 3 (ground)
terminals of the connector J489. The
voltage must be 12V.
Active damping.
Cannot manage the cab's position.

Id7581h

901

SFA (A102)

Compressor wear.

The number of cycles has
increased by 15% in 1 hour.

The compressor is running.
Active damping.
Cab position management possible.

Id7582h

902

SFA (A102)

The cab suspension
compressor is inoperative.

The compressor has been
running for 6 mn.

Active damping.
Cannot manage the cab's position.

Id7583h

903

SFA (A102)

Cab suspension failure.

No message from the left-hand
shock absorber 5 seconds after
starting.

Maximum tractor speed 15 km/h.
Active damping (Hard mode).
Cannot manage the cab's position.

Id7584h

904

SFA (A102)

Cab suspension failure.

No message from the right
hand shock absorber 5 seconds
after starting.

Maximum tractor speed 15 km/h.
Active damping (Hard mode).
Cannot manage the cab's position.

Id76D0h

613

SFA (A102)

Unable to read tractor
specific parameters in
EEPROM memory.

Non functional suspension
locked in its current position.

Check:
The SFA (A102) suspended axle module.

Id76D8h

621

SFA (A102)

Short-circuit on the On/Off
supply solenoid valve
(solenoid valve 1).

Non functional suspension
locked in its current position.

Check:
Supply solenoid valve 1 (Y321).

Id76D9h

622

SFA (A102)

Short-circuit on the supply of
down On/Off solenoid valve
(solenoid valve 2).

Non functional suspension
locked in its current position.

Check:
Down solenoid valve 2 (Y322).

Id76DAh

623

SFA (A102)

Short-circuit on the supply of
the transfer proportional
solenoid valve (Y331).

Non functional suspension
locked in its current position.

Check:
Transfer solenoid valve 3 (Y331).
Drive slow.

 

Id76DBh

624

SFA (A102)

Short-circuit on the supply of
the transfer proportional
solenoid valve (solenoid
valve 3).

Non functional suspension
locked in its current position.

Check:
Transfer solenoid valve 3 (Y331).

Id76DCh

625

SFA (A102)

Short-circuit on the supply of
the cumulator proportional
solenoid valve (solenoid
valve 4).

Non functional suspension
locked in its current position.

Check:
Cumulator solenoid valve 4 (Y332).

Id76DDh

626

SFA (A102)

Open circuit on the On/Off
supply solenoid valve
(solenoid valve 1).

Non functional suspension
locked in its current position.

Check:
Supply solenoid valve 1 (Y321).

Id76DEh

627

SFA (A102)

Open circuit on the down On/
Off solenoid valve (solenoid
valve 2).

Non functional suspension
locked in its current position.

Check:
Down solenoid valve 2 (Y322).

Id76DFh

628

SFA (A102)

Open circuit on the transfer
solenoid valve (3 solenoid
valve).

Non functional suspension
locked in its current position.

Check:
Transfer solenoid valve 3 (Y331).

Id76E0h

629

SFA (A102)

Open circuit on the transfer
proportional solenoid valve
(solenoid valve 3).

Non functional suspension
locked in its current position.

Check:
Transfer solenoid valve 3 (Y331).

Id76E2h

631

SFA (A102)

Open circuit on the
cumulator proportional
solenoid valve (solenoid
valve 4).

Non functional suspension
locked in its current position.

Check:
Cumulator solenoid valve 4 (Y332).

Id76E3h

632

SFA (A102)

Short-circuit to ground of the
supply On/Off solenoid valve
(solenoid valve 1).

Non functional suspension
locked in its current position.

Check:
Supply solenoid valve 1 (Y321).

Id76E4h

633

SFA (A102)

Short-circuit to ground of the
down On/Off solenoid valve
(solenoid valve 2).

Non functional suspension
locked in its current position.

Check:
Down solenoid valve 2 (Y322).

Id76E5h

634

SFA (A102)

Short circuit to ground of the
transfer solenoid valve
(solenoid valve 3).

Non functional suspension
locked in its current position.

Check:
Transfer solenoid valve 3 (Y331).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id76E6h

635

SFA (A102)

Short-circuit to ground of the
transfer proportional solenoid
valve (solenoid valve 3).

Non functional suspension
locked in its current position.

Check:
Transfer solenoid valve 3 (Y331).

Id76E7h

636

SFA (A102)

Short-circuit to ground of the
cumulator proportional
solenoid valve (solenoid
valve 4).

Non functional suspension
locked in its current position.

Check:
Cumulator solenoid valve 4 (Y332).

Id76E8h

637

SFA (A102)

Open circuit, short-circuit to
ground of the suspension's
right-hand position sensor.

Non functional suspension
locked in its current position.

Check:
RH suspension sensor (B234-1).

Id76E9h

638

SFA (A102)

Short-circuit on the supply of
the right-hand suspension
position sensor.

Non functional suspension
locked in its current position.

Check:
RH suspension sensor (B234-1).

Id76EAh

639

SFA (A102)

Open circuit, short-circuit to
ground of the suspension's
posotion sensor
or
Open circuit, short-circuit to
ground of the left-hand
suspension position sensor.

Non functional suspension
locked in its current position.

Check:
The suspension sensor (B220)
or
The suspension sensor (B234-2).

Id76ECh

641

SFA (A102)

Short-circuit to supply of the
suspension position sensor
or
Short-circuit on the supply of
the left-hand suspension
position sensor.

Non functional suspension
locked in its current position.

Check:
The suspension sensor (B220)
or
The suspension sensor (B234-2).

Id76EDh

642

SFA (A102)

Supply voltage too low (<
10,5 V).

Non functional suspension
locked in its current position.

Check:
– The voltage source (G001).
– The SFA (A102) suspended axle module.

Id78C4h

860

SFA (A102)

Front suspended axle
disconnected during a
sequence CSM.

The front axle is inoperative.

After 20 seconds, the tractor initializes,
then the sequence is relaunched.
If nothing happens, reset the CSM.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

BDG (A103)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id76F0h

BDG (A103)

Confirmation of engine
speed memorization.

Id76F1h

BDG (A103)

No message was transmitted
by the SFA module although
the configuration indicates its
presence.

The front axle suspension is
locked in its current position.

Check:
– The Powertrain CAN bus network.
– The SFA (A102) suspended axle module.
– The CAN network communication module
BDG (A103).

Id76F2h

BDG (A103)

No message was transmitted
by the HYD module although
the configuration indicates its
presence.

The hydraulic module
HYD (A60) and the associated
functions are inactive.

Check:
– The CLAAS vehicle CAN bus network.
– The hydraulic module HYD (A60).
– The CAN network communication module
BDG (A103).

Id76F3h

BDG (A103)

No message was transmitted
by the EXT module although
the configuration indicates its
presence.

The external function module
EXT (A62) and its associated
functions are inactive

Check:
– The CLAAS vehicle CAN bus network.
– The EXT terminal module (A62).
– The CAN network communication module
BDG (A103).

Id76F4h

BDG (A103)

No message was transmitted
by the Z+ module although
the configuration indicates its
presence.

The Z+ module and its
associated functions are
inactive.

Check:
– The CLAAS vehicle CAN bus network.
– The suspended cab module Z+.
– The CAN network communication module
BDG (A103).

Id76F5h

BDG (A103)

No message was transmitted
by the CVT module although
the configuration indicates its
presence.

The CVT module and its
associated functions are
inactive.

Check:
– The CLAAS vehicle CAN bus network.
– The CVT module.
– The CAN network communication module
BDG (A103).

Id76F6h

BDG (A103)

No message was transmitted
by the MFT module although
the configuration indicates its
presence.

The Cebis terminal module
MFT (A30) and its associated
functions can be inactive.

Check:
– The CLAAS vehicle CAN bus network.
– The Cebis terminal module MFT (A30).
– The CAN network communication module
BDG (A103).

 

 

Id76F7h

BDG (A103)

No message has been
transmitted by the WLP
module for at least 5
seconds.

The WLP (A104) working light
module and its associated
functions may be inactive.

Check:
– The CLAAS vehicle CAN bus network.
– The working light module WLP (A104).
– The CAN network communication module
BDG (A103).

Id76F8h

BDG (A103)

No message has been
transmitted by the MFA
module for at least 5
seconds.

The MFA (A100) multifunction
armrest module and its
associated functions may be
inactive.

Check:
– The CLAAS vehicle CAN bus network.
– The MFA (A100) armrest multifunction
module.
– The CAN network communication module
BDG (A103).

Id76F9h

BDG (A103)

No message has been
transmitted by the DBD
module for at least 5
seconds.

The DBD (A101) instrument
panel module and its associated
functions may be lost.

Check:
– The CLAAS vehicle CAN bus network.
– The instrument panel module DBD (A101).
– The CAN network communication module
BDG (A103).

Id76FAh

BDG (A103)

No message has been
transmitted by the ENG
module for at least 5
seconds.

The ENG (A15) engine module
and its associated functions
may be lost.

Check:
– The Powertrain CAN bus network.
– The engine module ENG (A15).
– The CAN network communication module
BDG (A103).

Id76FBh

BDG (A103)

No message has been
transmitted by the TR1
module for at least 5
seconds.

The TR1 (A57-1) transmission
module and its associated
functions may be lost.

Check:
– The Powertrain CAN bus network.
– The TR1 transmission module (A57-1).
– The CAN network communication module
BDG (A103).

Id76FCh

BDG (A103)

No message has been
transmitted by the TR2
module for at least 5
seconds.

The TR2 (A57-2) transmission
module and its associated
functions may be lost.

Check:
– The Powertrain CAN bus network.
– The TR2 transmission module (A57-2).
– The CAN network communication module
BDG (A103).

Id76FDh

BDG (A103)

No message has been
transmitted by the TR3
module for at least 5
seconds.

The TR3 (A57-3) transmission
module and its associated
functions may be lost.

Check:
– The Powertrain CAN bus network.
– The TR3 transmission module (A57-3).
– The CAN network communication module
BDG (A103).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id76FEh

BDG (A103)

No message has been
transmitted by the REH
module for at least 5
seconds.

The REH (A58) lifting module
and its associated functions
may be lost.

Check:
– The Powertrain CAN bus network.
– The lifting module REH (A58).
– The CAN network communication module
BDG (A103).

Id76FFh

BDG (A103)

Short-circuit to the 12V on
the CLAAS vehicle CAN bus.

Check:
The CLAAS vehicle CAN bus network.

Id7700h

BDG (A103)

Short-circuit to the ground on
the CLAAS vehicle CAN bus.

Check:
– The CLAAS vehicle CAN bus network.
– The CAN network communication module
BDG (A103).

Id7701h

BDG (A103)

The BDG module no longer
transmits any messages on
the CLAAS vehicle CAN bus
due to a number of CAN
frame errors too high on the
CLAAS vehicle CAN bus

Check:
– The CLAAS vehicle CAN bus network.
– The CAN network communication module
BDG (A103).

Id7702h

BDG (A103)

Short-circuit to the 12V on
the Powertrain CAN bus.

Check:
The Powertrain CAN bus network.
The CAN network communication module
BDG (A103).

Id7703h

BDG (A103)

Short-circuit to the ground on
the Powertrain CAN bus.

Check:
– The Powertrain CAN bus network.
– The CAN network communication module
BDG (A103).

Id7704h

BDG (A103)

The BDG module no longer
transmits any messages on
the Powertrain CAN bus due
to a number of CAN frame
errors too high on the
Powertrain CAN bus.

Check:
– The Powertrain CAN bus network.
– The CAN BDG network communication
module (A103).

Id7705h

BDG (A103)

Engine controller
disconnected during a
sequence CSM.

The engine controller is
inoperative.

After 20 seconds, the tractor initializes,
then the sequence is relaunched.
If nothing happens, reset the CSM.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id7706h

BDG (A103)

Tranmission module TR2
(A57-2) has detected
communication loss with the
external function module
EXT (A62) during a CSM
sequence.

Sequence stopped. Wait for the sequence
to be relaunched.
Check:
– The TR2 transmission module (A57-2).
– The external function module EXT (A62).

Id7707h

BDG (A103)

Message missing on the
level of the stop sequence
button CSM.

Functions unavailable.

Back to normal mode when the message
is received again.

Id7708h

BDG (A103)

Message missing on the
level of button 1 and 2 in the
CSM sequence.

Functions unavailable.

Back to normal mode when the message
is received again.

Id7709h

BDG (A103)

Message missing on the
level of the front external
control buttons.

Functions unavailable.

Back to normal mode when the message
is received again.

Id770Ah

BDG (A103)

Message missing on the
level of the function 1 and 2
button.

Functions unavailable.

Back to normal mode when the message
is received again.

Id770Bh

BDG (A103)

Message missing on the
level of the function 3 and 4
button.

Functions unavailable.

Back to normal mode when the message
is received again.

Id770Ch

BDG (A103)

Message missing on the
level of the ITE.

No message from the ITE
during 5 seconds.

Back to normal mode when the message
is received again.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

ENG (A15)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id7710h

190 00

ENG (A15)

Extreme engine overspeed.

The fuel supply of the common
rail by the high pressure pump
is off.

Abnormal use of the engine.
Check the engine application.

Id7711h

676 03

ENG (A15)

High voltage on the glow
plug relay.

Difficult start.
Irregular engine running.

Check:
– The glow plugs (R78).
– The preheating relay (K1).

Id7712h

676 04

ENG (A15)

No return voltage on the glow
plug relay.

Difficult start in extreme cold.

Check:
– The glow plugs (R78).
– The preheating relay (K1).

Id7713h

898 09

ENG (A15)

The ENG (A15) engine
module does not receive the
accelerator information on
the Powertrain CAN bus or
this information is in error on
the Powertrain CAN bus.

The engine remains in idle
speed.

Check:
– The Powertrain CAN bus network.
– The TR2 (A57-2) module.
– The engine module ENG (A15).

Id7714h

1568 02

ENG (A15)

The ENG (A15) engine
module receives no
information from torque
curve selection on the
Powertrain CAN bus or this
information is in error on the
Powertrain CAN bus.

The Claas Sequence
Management is inactive.
The lowest power curve is
selected by default.

Check:
– The Powertrain CAN bus network.
– The TR2 (A57-2) module.
– The engine module ENG (A15).

Id7715h

2004 09

ENG (A15)

Communication error on the
Powertrain CAN bus.

The engine remains in idle
speed.

Check:
– The Powertrain CAN bus network.
– The TR2 (A57-2) module.
– The engine module ENG (A15).

Id7716h

2000 13

ENG (A15)

Engine/transmission
configuration error.

The engine stays in idle speed
after 1 minute running.

Check:
– The configuration of the TR1 (A57-
1), TR2 (A57-2), TR3 (A57-3) transmission
modules and ENG (A15) engine module.

Id7717h

2005 09

ENG (A15)

Communication error on the
Powertrain CAN bus.

The engine remains in idle
speed.

Check:
– The Powertrain CAN bus network.
– The TR2 (A57-2) module.
– The engine module ENG (A15).

Id7718h

97 03

ENG (A15)

Voltage of the signal high
presence of water in the fuel.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The water presence sensor (B225).
– The engine module ENG (A15).

Id7719h

97 04

ENG (A15)

Voltage of the signal low
presence of water in the fuel.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The water presence sensor (B225).
– The engine module ENG (A15).

Id771Ah

97 16

ENG (A15)

Presence of water detected
in the fuel.

Engine power is reduced to
50%.

Empty the decanter prefilter. Restart the
tractor.
The tractor returns to the normal mode
when the error disappears.

Id771Bh

102 02

ENG (A15)

Air pressure in the intake
manifold non valid.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– Intake air pressure sensor (B51).
– The engine module ENG (A15).

Id771Ch

102 03

ENG (A15)

High intake manifold air
pressure voltage.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– Intake air pressure sensor (B51).
– The engine module ENG (A15).

Id771Dh

102 04

ENG (A15)

Low air pressure at intake
manifold voltage.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– Intake air pressure sensor (B51).
– The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id771Eh

103 00

ENG (A15)

Turbocharger speed
excessively high.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).

Check:
– Turbocharger linkages.
– Turbocharger speed sensor (B226).
– Turbocharger.

Id771Fh

103 05

ENG (A15)

Intensity of the turbocharger
speed sensor low.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– Turbocharger speed sensor (B226).
– The engine module ENG (A15).

Id7720h

103 06

ENG (A15)

Intensity of the turbocharger
speed sensor high.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– Turbocharger speed sensor (B226).
– The engine module ENG (A15).

Id7721h

103 08

ENG (A15)

Turbocharger speed non
valid.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– Turbocharger speed sensor (B226).
– The engine module ENG (A15).

Id7722h

103 31

ENG (A15)

Turbocharger speed missing

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– Turbocharger speed sensor (B226).
– The engine module ENG (A15).

Id7723h

105 00

ENG (A15)

Air mix temeprature
excessively high.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 40% its nominal power
(power recovered: 20% per
minute).

Check:
– The mixed air temperature sensor (B223).
– The engine module ENG (A15).

Id7724h

105 03

ENG (A15)

Input voltage of the mixed air
high tempertaure sensor.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The mixed air temperature sensor (B223).
– The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id7725h

105 04

ENG (A15)

Input temperature of the
mixed air low temperature
sensor.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The mixed air temperature sensor (B223).
– The engine module ENG (A15).

Id7726h

105 15

ENG (A15)

Temperature of mixed air
slightly high.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The mixed air temperature sensor (B223).
– The engine module ENG (A15).

Id7727h

105 16

ENG (A15)

Temperature of mixed air
averagely high.

The ENG (A15) engine
calculator reduces engine
power by 5% per minute until it
reaches 80% its nominal power
(power recovered: 5% per
minute).

Check:
– The mixed air temperature sensor (B223).
– The engine module ENG (A15).

Id7728h

108 02

ENG (A15)

Internal barometric pressure
of the engine module non
valid.

The ENG (A15) engine
calculator uses a default
barometric pressure to run the
engine.

Check:
– The engine module ENG (A15).

Id7729h

110 00

ENG (A15)

Engine coolant temperature
excessively high.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 40% its nominal power
(power recovered: 20% per
minute).

Check:
– The engine cooling circuit.
– The engine coolant temperature sensor
(B45).
– The engine module ENG (A15).

Id772Ah

110 03

ENG (A15)

Input voltage of the engine
coolant high.

The ENG (A15) engine coolant
uses a default coolant
temperature of 90°C.

Check:
– The engine cooling circuit.
– The engine coolant temperature sensor
(B45).
– The engine module ENG (A15).

Id772Bh

110 04

ENG (A15)

Input voltage of the engine
coolant low.

The ENG (A15) engine coolant
uses a default coolant
temperature of 90°C.

Check:
– The engine cooling circuit.
– The engine coolant temperature sensor
(B45).
– The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id772Ch

110 15

ENG (A15)

Temperature of the engine
coolant slightly high.

The engine runs normally.

Check:
– The engine cooling circuit.
– The engine coolant temperature sensor
(B45).
– The engine module ENG (A15).

Id772Dh

110 16

ENG (A15)

Temperature of the engine
coolant averagely high.

The ENG (A15) engine
calculator reduces engine
power by 5% per minute until it
reaches 80% its nominal power
(power recovered: 5% per
minute).

Check:
– The engine cooling circuit.
– The engine coolant temperature sensor
(B45).
– The engine module ENG (A15).

Id772Eh

110 17

ENG (A15)

Engine coolant temeprature
slightly low.

The engine runs normally.

Check:
– The engine cooling circuit.
– The engine coolant temperature sensor
(B45).
– The engine module ENG (A15).

Id772Fh

157 03

ENG (A15)

Input voltage of the fuel
pressure sensor in the
common rail high.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).
The ENG (A15) engine
calculator manages the high
pressure pump in order to
establish a 2 000 bar pressure
in the common rail (opening the
pressure restricter in the
common rail).

Check:
– The fuel pressure sensor of the common
rail (B42).
– The engine module ENG (A15).

Id7730h

157 04

ENG (A15)

Input voltage of the fuel
pressure sensor in the
common rail low.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).
The ENG (A15) engine
calculator manages the high
pressure pump in order to
establish a 2 000 bar pressure
in the common rail (opening the
pressure restricter in the
common rail).

Check:
– The fuel pressure sensor of the common
rail (B42).
– The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id7731h

157 10

ENG (A15)

Loss of pressure in the fuel
rail.

The engine cannot start or
cannot gain power.

Check:
– Supply ducts and fittings.
– The pressure restricter.
– The electronic injectors (Y320).

Id7732h

157 17

ENG (A15)

Fuel pressure in the common
rail not reached.

The engine will not start.

Check:
– Supply ducts and fittings.
– The fuel prefilter and filter.
– The pressure restricter.
– The high pressure pump.

Id7733h

158 17

ENG (A15)

Error when powering off the
ENG (A15) engine module.

The ENG (A15) engine
calculator does not switch to
standby.
The tractor battery may be
discharged.

Check:
– The key contact (S64).

Id7734h

174 00

ENG (A15)

Fuel temperature
excessively high.

The ENG (A15) engine
calculator reduces engine
power by 5% per minute until it
reaches 80% its nominal power
(power recovered: 5% per
minute).

Check:
– Supply ducts and fittings.
– The overflow valve.
– The fuel cooler.
– The high pressure pump.

Id7735h

174 03

ENG (A15)

Fuel temperature input
voltage high.

The ENG (A15) engine
calculator uses a default fuel
temperature of 40°C.

Check:
– The fuel temperature sensor (B44).
– The engine module ENG (A15).

Id7736h

174 04

ENG (A15)

Fuel temperature input
voltage low.

The ENG (A15) engine
calculator uses a default fuel
temperature of 40°C.

Check:
– The fuel temperature sensor (B44).
– The engine module ENG (A15).

Id7737h

174 16

ENG (A15)

Fuel temperature moderately
high.

The engine runs normally.

Check:
– Supply ducts and fittings.
– The overflow valve.
– The fuel cooler.
– The high pressure pump.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7738h

412 00

ENG (A15)

Temperature of cooled
exhaust gases excessively
high.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).

Check:
– The cooled exhaust gas temperature
sensor (B221).
– The coolant level.
– The coolant thermostat.
– The exhaust gas recycling cooler.

Id7739h

412 03

ENG (A15)

Input voltage of the
temperature of cooled
exhaust gases high.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The cooled exhaust gas temperature
sensor (B221).
– The engine module ENG (A15).

Id773Ah

412 04

ENG (A15)

Input voltage of cooled
exhaust gases temperature
low.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The cooled exhaust gas temperature
sensor (B221).
– The engine module ENG (A15).

Id773Bh

412 15

ENG (A15)

Temperature of cooled
exhaust gases slightly high.

The ENG (A15) engine
calculator reduces the engine
power instantly to 95% of its
nominal power (power recovery
of 5% per minute).

Check:
– The harness and its connectors.
– The general condition of the cooling circuit.
– The cooled exhaust gas temperature
sensor (B221).
– A possible short-circuit.

Id773Ch

412 16

ENG (A15)

Temperature of cooled
exhaust gases averagely
high.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).

Check:
– The cooled exhaust gas temperature
sensor (B221).
– The coolant level.
– The coolant thermostat.
– The exhaust gas recycling cooler.

Id773Dh

611 03

ENG (A15)

Short-circuit on the power
supply of the electronic
injection device.

The engine misfires and/or
grey/black smoke is seen.

Check:
– The electronic injectors (Y320).

Id773Eh

611 04

ENG (A15)

Short-circuit to ground of the
electronic injection device

The engine misfires and/or
grey/black smoke is seen.

Check:
– For a possible short circuit to earth.
– The electronic injectors (Y320).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id773Fh

627 01

ENG (A15)

Supply voltage of the ENG
engine module out of
tolerance.

The engine may fail to start.

Check:
– The battery voltage.
– The supply of the ENG (A15) engine
module.

Id7740h

629 13

ENG (A15)

Error of the ENG engine
module.

The engine will not start.

Check:
– The engine module ENG (A15).

Id7741h

636 02

ENG (A15)

Signal of the position sensor
of the high pressure pump
non valid.

The start time is extended.
The ENG (A15) engine
calculator uses the signal of the
crankshaft position sensor to
determine the piston's position.

Check:
– The position sensor of the (B232) high
pressure pump.
– The engine module ENG (A15).

Id7742h

636 05

ENG (A15)

Intensity of the position
sensor of the high pressure
pump low.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The position sensor of the (B232) high
pressure pump.
– The engine module ENG (A15).

Id7743h

636 06

ENG (A15)

Intensity of the position
sensor of the high pressure
pump high.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The position sensor of the (B232) high
pressure pump.
– The engine module ENG (A15).

Id7744h

636 08

ENG (A15)

No signal from the position
sensor of the high pressure
pump.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The position sensor of the (B232) high
pressure pump.
– The engine module ENG (A15).

Id7745h

636 10

ENG (A15)

Format of the position signal
of the high pressure pump
non valid.

The start time is extended.
At the precise moment when
the anomaly code is declared,
the engine might shudder or
stall but it should restart.
The ENG (A15) engine
calculator uses the signal of the
crankshaft position sensor to
determine the piston's position.

Check:
– The position sensor of the (B232) high
pressure pump.
– The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id7746h

637 02

ENG (A15)

Signal of the crankshaft
position sensor non valid

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).

Check:
– The crankshaft position sensor (B231).
– The engine module ENG (A15).

Id7747h

637 05

ENG (A15)

Intensity of the crankshaft
position sensor low.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The crankshaft position sensor (B231).
– The engine module ENG (A15).

Id7748h

637 06

ENG (A15)

Intensity of the crankshaft
position sensor high.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The crankshaft position sensor (B231).
– The engine module ENG (A15).

Id7749h

637 07

ENG (A15)

Position of the crankshaft/
high pressure pump slightly
desynchronized.

The engine may stall, then
resart or not.

Check:
– The shimming of the high pressure pump's
position.
– The timing gear of the crankshaft and
sensor.
– The crankshaft position sensor (B231).
– The position sensor of the (B232) high
pressure pump.

Id774Ah

637 08

ENG (A15)

No signal from the crankshaft
position sensor.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).

Check:
– The crankshaft position sensor (B231).
– The engine module ENG (A15).

Id774Bh

637 10

ENG (A15)

Format of the crankshaft
position signal non valid.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).

Check:
– The crankshaft position sensor (B231).
– The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id774Ch

641 04

ENG (A15)

Turbocharger actuator error.

The engine may have a power
loss as the turbocharger
actuator does not react.

Check:
– Turbocharger actuator (M37).
– The engine module ENG (A15).

Id774Dh

641 12

ENG (A15)

Communication error
between the ENG engine
module/turbocharger
actuator.

The actuator approaches the
20% closed position and stays
in this position.

Check:
– Turbocharger actuator (M37).
– The engine module ENG (A15).

Id774Eh

641 13

ENG (A15)

Error in the values of the
turbocharger actuator in the
diagnostic mode.

The engine runs normally.

Check:
– The linkages of the turbocharger actuator.
– Turbocharger actuator (M37).
– Turbocharger.

Id774Fh

641 16

ENG (A15)

Temperature of the
turbocharger actuator
averagly high.

The engine runs normally.

Check:
– The cooling circuit of the actuator.
– Turbocharger actuator (M37).
– Turbocharger.
– The engine module ENG (A15).

Id7750h

651 02

ENG (A15)

Reference of the injector of
cylinder n°1 non valid

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°1.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-1).

Id7751h

651 05

ENG (A15)

Open circuit on the electronic
injector of cylinder n°1.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°1 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-1).

Id7752h

651 06

ENG (A15)

Short-circuit of the electronic
injector on cylinder n°1.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°1 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-1).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7753h

651 07

ENG (A15)

Mechanical failure of the
electronic injector of cylinder
n°1.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°1 is inoperative.

Check:
– The supply ducts and lateral supply tube of
the electronic injector.
– The flow restricter.
– Electronic injector (Y320-1).
– The engine module ENG (A15).

Id7754h

651 13

ENG (A15)

QR code non valid of the
electronic injector of cylinder
n°1.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°1.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-1).

Id7755h

652 02

ENG (A15)

Reference of the injector of
cylinder n°2 non valid.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°2.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-2).

Id7756h

652 05

ENG (A15)

Open circuit on the electronic
injector of cylinder n°2.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°2 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-2).

Id7757h

652 06

ENG (A15)

Short-circuit of the electronic
injector on cylinder n°2.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°2 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-2).

Id7758h

652 07

ENG (A15)

Mechanical failure of the
electronic injector of cylinder
n°2.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°2 is inoperative.

Check:
– The supply ducts and lateral supply tube of
the electronic injector.
– The flow restricter.
– Electronic injector (Y320-2).
– The engine module ENG (A15).

Id7759h

652 13

ENG (A15)

QR code non valid of the
electronic injector of cylinder
n°2.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°2.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-2).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id775Ah

653 02

ENG (A15)

Reference of the injector of
cylinder n°3 non valid.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°3.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-3).

Id775Bh

653 05

ENG (A15)

Open circuit on the electronic
injector of cylinder n°3.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°3 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-3).

Id775Ch

653 06

ENG (A15)

Short-circuit of the electronic
injector on cylinder n°3.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°3 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-3).

Id775Dh

653 07

ENG (A15)

Mechanical failure of the
electronic injector of cylinder
n°3.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°3 is inoperative.

Check:
– The supply ducts and lateral supply tube of
the electronic injector.
– The flow restricter.
– Electronic injector (Y320-3).
– The engine module ENG (A15).

Id775Eh

653 13

ENG (A15)

QR code non valid of the
electronic injector of cylinder
n°3.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°4.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-3).

Id775Fh

654 02

ENG (A15)

Reference of the injector of
cylinder n°4 non valid.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°4.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-4).

Id7760h

654 05

ENG (A15)

Open circuit on the electronic
injector of cylinder n°4.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°4 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-4).

Id7761h

654 06

ENG (A15)

Short-circuit of the electronic
injector on cylinder n°4.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°4 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-4).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id7762h

654 07

ENG (A15)

Mechanical failure of the
electronic injector of cylinder
n°4.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°4 is inoperative.

Check:
– The supply ducts and lateral supply tube of
the electronic injector.
– The flow restricter.
– Electronic injector (Y320-4).
– The engine module ENG (A15).

Id7763h

654 13

ENG (A15)

QR code non valid of the
electronic injector of cylinder
n°4.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°4.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-4).

Id7764h

655 02

ENG (A15)

Reference of the injector of
cylinder n°5 non valid.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°5.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-5).

Id7765h

655 05

ENG (A15)

Open circuit on the electronic
injector of cylinder n°5.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°5 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-5).

Id7766h

655 06

ENG (A15)

Short-circuit of the electronic
injector on cylinder n°5.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°5 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-5).

Id7767h

655 07

ENG (A15)

Mechanical failure of the
electronic injector of cylinder
n°5.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°5 is inoperative.

Check:
– The supply ducts and lateral supply tube of
the electronic injector.
– The flow restricter.
– Electronic injector (Y320-5).
– The engine module ENG (A15).

Id7768h

655 13

ENG (A15)

QR code non valid of the
electronic injector of cylinder
n°5.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°5.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-5).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7769h

656 02

ENG (A15)

Reference of the injector of
cylinder n°6 non valid.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°6.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-6).

Id776Ah

656 05

ENG (A15)

Open circuit on the electronic
injector of cylinder n°6.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°6 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-6).

Id776Bh

656 06

ENG (A15)

Short-circuit of the electronic
injector on cylinder n°6.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°6 is inoperative.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-6).

Id776Ch

656 07

ENG (A15)

Mechanical failure of the
electronic injector of cylinder
n°6.

The engine will run with
difficulty and will misfire as the
ignition of the injector in cylinder
n°6 is inoperative.

Check:
– The supply ducts and lateral supply tube of
the electronic injector.
– The flow restricter.
– Electronic injector (Y320-6).
– The engine module ENG (A15).

Id776Dh

656 13

ENG (A15)

QR code non valid of the
electronic injector of cylinder
n°6.

The engine may run with
difficulty due to invalid
calibration of the injector of
cylinder n°6.

Check:
– The engine module ENG (A15).
– Electronic injector (Y320-6).

Id776Eh

1136 00

ENG (A15)

Temperature of the engine
module excessively high.

The ENG (A15) engine
calculator reduces engine
speed by 600 rev/min and limits
engine speed at 1 200 rev/min
(returning to engine speed after
restarting).

Check:
– The engine module ENG (A15).

Id776Fh

1136 16

ENG (A15)

Temperature of the engine
module averagely high.

The ENG (A15) engine
calculator reduces engine
speed by 600 rev/min and limits
engine speed at 1 200 rev/min
(returning to engine speed after
restarting).

Check:
– The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7770h

1172 03

ENG (A15)

Input voltage of the
turbocharger intake air
temperature high.

The ENG (A15) engine
calculator uses a default intake
air temperature of 30°C.

Check:
– The intake air temperature sensor (B1).
– The engine module ENG (A15).

Id7771h

1172 04

ENG (A15)

Input voltage of the
turbocharger intake air
temperature low.

The ENG (A15) engine
calculator uses a default intake
air temperature of 30°C.

Check:
– The intake air temperature sensor (B1).
– The engine module ENG (A15).

Id7772h

1180 00

ENG (A15)

Intake air temperature of the
turbocharger excessively
high.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).

Check:
– The intake air temperature sensor (B1).
– The air filter.
– The engine fan.
– The supercharging air circuit

Id7773h

1180 16

ENG (A15)

Turbocharger intake air
temperature averagely high.

The ENG (A15) engine
calculator reduces the engine
power instantly to 95% of its
nominal power (power recovery
of 5% per minute).

Check:
– The intake air temperature sensor (B1).
– The air filter.
– The engine fan.
– The supercharging air circuit

Id7774h

1347 03

ENG (A15)

Intensity of the high pressure
pump solenoid valve high.

The engine will run abnormally
according to the severity of the
problem.

Check:
– The high pressure pump solenoid valve for
high pressure fuel (Y344).

Id7775h

1347 05

ENG (A15)

Disparity of intensity of the
high pressure pump solenoid
valve.

The engine's power increases
juste for the time required for
the high pressure common rail
pressure to exceed the upper
threshold of the pressure
restricter (pressure restricter of
the common rail opens).

Check:
– The high pressure pump solenoid valve for
high pressure fuel (Y344).

Id7776h

1347 07

ENG (A15)

Error in fuel pressure of the
common rail

The engine calculator instructs
the high pressure pump to
increase or reduce the quantity
of fuel in the common rail.
The engine can misfire or rune
irregularly.
The engine can provide low
power.

Check:
– Supply ducts and fittings.
– Timing of the high pressure pump.
– The fuel pressure sensor of the common
rail (B42).
– The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id7777h

1569 31

ENG (A15)

Reduction of fuel input.

The ENG (A15) engine
calculator reduces fuel supply
to protect the engine

Check the following error codes:
Id771Ah, Id771Eh, Id7723h, Id7727h,
Id7729h, Id772Dh, Id772Fh, Id7730h,
Id7734h, Id7738h, Id773Ch, Id7746h,
Id7749h, Id774Ah, Id774Bh, Id7772h,
Id7773h, Id7778h, Id777Ch, Id777Fh,
Id7780h, Id7781h, Id7785h, Id7787h.

Id7778h

2630 00

ENG (A15)

Fresh air intake temperature
excessively high.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 40% its nominal power
(power recovered: 20% per
minute).

Check:
– The air cooler (intercooler).
– The fresh air intake temperature sensor
(B222).

Id7779h

2630 03

ENG (A15)

Input voltage of the fresh air
intake temperature high.

The ENG (A15) engine
calculator uses a default intake
fresh air temperature of 50°C.
The engine protection function
ensured by the ENG (A15)
engine calculator with the fresh
air maximum temperature EGR
is deactivated.

Check:
– The fresh air intake temperature sensor
(B222).
– The engine module ENG (A15).

Id777Ah

2630 04

ENG (A15)

Input voltage of the fresh air
intake temperature low.

The ENG (A15) engine
calculator uses a default intake
fresh air temperature of 50°C.
The engine protection function
ensured by the ENG (A15)
engine calculator with the fresh
air maximum temperature EGR
is deactivated.

Check:
– The fresh air intake temperature sensor
(B222).
– The engine module ENG (A15).

Id777Bh

2630 15

ENG (A15)

Input voltage of the fresh air
intake temperature slightly
high.

The engine runs normally.

Check:
– The air cooler (intercooler).
– The fresh air intake temperature sensor
(B222).
– The engine module ENG (A15).

Id777Ch

2630 16

ENG (A15)

Fresh air intake temperature
averagely high.

The ENG (A15) engine
calculator reduces engine
power by 5% per minute until it
reaches 80% its nominal power
(power recovered: 5% per
minute).

Check:
– The air cooler (intercooler).
– The fresh air intake temperature sensor
(B222).
– The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id777Dh

2659 02

ENG (A15)

Flow rate/temperature gap
for exhaust gas recycling.

The engine runs normally
without considering the
information delivered by the
sensor in error.

Check:
– The air intake temperature and pressure
sensors B222, B042, B221.
– The engine module ENG (A15).

Id777Eh

2659 15

ENG (A15)

Flow rate of recycled exhaust
gases slightly high.

-

Check:
– The EGR (M38) actuator.
– The engine module ENG (A15).

Id777Fh

2659 17

ENG (A15)

Flow rate of recycled exhaust
gases slightly low.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 80% its nominal power
(power recovered: 20% per
minute).

Check:
– The EGR (M38) actuator.
– The engine module ENG (A15).

Id7780h

2790 16

ENG (A15)

Turbocharger exit
temperature averagely high.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).

Check:
– The following error codes: Id7770h,
Id7771h, Id7778h, Id7779h, Id777Ah,
Id777Bh, Id777Ch.
– The air filter.
– The engine fan.

Id7781h

2791 02

ENG (A15)

Position of the EGR exhasut
gas recycling valve non valid.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 80% its nominal power
(power recovered: 20% per
minute).

Check:
– The EGR (M38) actuator.
– The engine module ENG (A15).

Id7782h

2791 03

ENG (A15)

Signal of the EGR exhaust
gas recycling valve above
maximum tolerance.

This error code produces the
Id7784h, Id7785h error codes,
generating a power reduction.

Check:
– The EGR (M38) actuator.
– The engine module ENG (A15).

Id7783h

2791 04

ENG (A15)

Signal of the EGR exhaust
gas recycling valve above
minimum tolerance.

This error code produces the
Id7784h, Id7785h error codes,
generating a power reduction.

Check:
– The EGR (M38) actuator.
– The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7784h

2791 07

ENG (A15)

Command error of the
exhaust gas recycling valve.

If the
Id7782h, Id7783h, Id7790h, Id7
791h error codes also appear,
run the procedure for these
codes first.

Check:
– The EGR (M38) actuator.
– The engine module ENG (A15).

Id7785h

2791 13

ENG (A15)

EGR exhaust gas recycling
valve out of calibration.

If the
Id7782h, Id7783h, Id7790h, Id7
791h error codes also appear,
run the procedure for these
codes first.
The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 80% its nominal power
(power recovered: 20% per
minute).

Check:
– The EGR (M38) actuator.
– The engine module ENG (A15).

Id7786h

2791 31

ENG (A15)

Calibration error of the EGR
exhaust gas recycling valve.

The engine runs normally while
ignoring the calibration error of
the EGR exhaust gas recycling
valve.

Check:
– The EGR (M38) actuator.
– The engine module ENG (A15).

Id7787h

2795 07

ENG (A15)

Gap in the position of the
turbocharger actuator.

The ENG (A15) engine
calculator reduces engine
power by 20% per minute until it
reaches 50% its nominal power
(power recovered: 20% per
minute).

Check:
– Turbocharger actuator (M37).
– Turbocharger linkages.
– Turbocharger.

Id7788h

3509 03

ENG (A15)

Reference voltage of the fuel
pressure sensor of the
common rail high

The ENG (A15) engine
calculator is trying to operate
normally.

Check:
– The fuel pressure sensor of the common
rail (B42).
– The engine module ENG (A15).

Id7789h

3509 04

ENG (A15)

Reference voltage of the fuel
pressure sensor on the lower
common rail.

The ENG (A15) engine
calculator is trying to operate
normally.

Check:
– The fuel pressure sensor of the common
rail (B42).
– The engine module ENG (A15).

Id778Ah

3510 03

ENG (A15)

Reference voltage (5V) of
the pressure, temperature
and water presence sensors
high.

The ENG (A15) engine
calculator is trying to operate
normally.

Check:
The engine module ENG (A15).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id778Bh

3510 04

ENG (A15)

Reference voltage (5V) of
the pressure, temperature,
water presence sensors low.

The ENG (A15) engine
calculator is trying to operate
normally.

Check:
The engine module ENG (A15).

Id778Ch

3511 03

ENG (A15)

Reference voltage (5V) high.
Not used.

The ENG (A15) engine
calculator is trying to operate
normally.

Check:
The engine module ENG (A15).

Id778Dh

3511 04

ENG (A15)

Reference voltage (5V) low.
Not used.

The ENG (A15) engine
calculator is trying to operate
normally.

Check:
The engine module ENG (A15).

Id778Eh

3512 03

ENG (A15)

Reference voltage (5V) high.
Not used.

The ENG (A15) engine
calculator is trying to operate
normally.

Check:
The engine module ENG (A15).

Id778Fh

3512 04

ENG (A15)

Reference voltage (5V) low.
Not used.

The ENG (A15) engine
calculator is trying to operate
normally.

Check:
The engine module ENG (A15).

Id7790h

3513 03

ENG (A15)

Reference voltage (5V) of
the EGR exhaust gas
recycling valve position
sensor high.

The ENG (A15) engine
calculator is trying to operate
normally.

Check:
– The EGR (M38) actuator.
– The engine module ENG (A15).

Id7791h

3513 04

ENG (A15)

Reference voltage (5V) of
the EGR exhaust gas
recycling valve position
sensor low.

The ENG (A15) engine
calculator is trying to operate
normally.

Check:
– The EGR (M38) actuator.
– Potential short-circuit to ground of the 5V
supply.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

MFT (A30)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id7877h

MFT (A30)

Internal error of the Cebis
terminal.

Random operation of the Cebis
terminal.

Check:
The Cebis terminal module MFT (A30).

Id7878h

MFT (A30)

Brightness sensor of the
terminal out of service.

Automatic control of brightness
of the terminal is inactive.
Manual brightness check.

Check:
The Cebis terminal module MFT (A30).

Id7879h

MFT (A30)

Internal temperature sensor
of the terminal out of service.

The internal temperature sensor
is inactive.

Check:
The Cebis terminal module MFT (A30).

Id787Ah

MFT (A30)

Voltage delivered by the
loudspeaker too low.

The loudspeaker of the Cebis
terminal is active.

Check:
– The loudspeaker of the Cebis terminal
(C22).
– The Cebis terminal module MFT (A30).

Id787Bh

MFT (A30)

Voltage delivered by the
loudspeaker too high.

The loudspeaker of the Cebis
terminal is active.

Check:
– The loudspeaker of the Cebis terminal
(C22).
– The Cebis terminal module MFT (A30).

Id787Ch

MFT (A30)

Short-circuit to the 12V on
the CLAAS vehicle CAN bus.

The Cebis terminal no longer
emits on the CAN but can
receive.

Check:
– The CLAAS vehicle CAN bus network.
– The Cebis terminal module MFT (A30).

Id787Dh

MFT (A30)

Short-circuit to the ground on
the CLAAS vehicle CAN bus.

Check:
– The CLAAS vehicle CAN bus network.
– The Cebis terminal module MFT (A30).

 

Id787Eh

MFT (A30)

The CLAAS vehicle CAN bus
component of the MFT
module is faulty.

Check:
– The CLAAS vehicle CAN bus network.
– The Cebis terminal module MFT (A30).

 

Id787Fh

MFT (A30)

The Cebis terminal no longer
emits messages over the
CLAAS vehicle CAN bus due
to too many CAN frame
errors over the
CLAAS vehicle CAN bus.

Check:
– The CLAAS vehicle CAN bus network.
– The Cebis terminal module MFT (A30).

 

 

 

EXT (A62)

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

Id7880h

EXT (A62)

Short-circuit to the 12V on
the CLAAS vehicle CAN bus.

Check:
– The CLAAS vehicle CAN bus network.
– The external function module EXT (A62).

Id7881h

EXT (A62)

Short-circuit to the ground on
the CLAAS vehicle CAN bus

Check:
– The CLAAS vehicle CAN bus network.
– The external function module EXT (A62).

Id7882h

EXT (A62)

The EXT module no longer
transmits any messages on
the CLAAS vehicle CAN bus
due to a number of CAN
frame errors too high on the
CLAAS vehicle CAN bus.

Check:
– The CLAAS vehicle CAN bus network.
– The external function module EXT (A62).

Id7883h

EXT (A62)

The CLAAS vehicle CAN bus
component of the EXT
module is faulty.

Check:
– The CLAAS vehicle CAN bus network.
– The external function module EXT (A62).

Id7884h

EXT (A62)

Short-circuit to the 12V on
the ISO CAN bus.

Check:
– The ISO CAN bus network.
– The external function module EXT (A62).

Id7885h

EXT (A62)

Short-circuit to the ground on
the ISO CAN bus.

Check:
– The ISO CAN bus network.
– The external function module EXT (A62).

Id7886h

EXT (A62)

The EXT module no longer
transmits any messages on
the ISO CAN bus due to a
number of CAN frame errors
too high on the
ISO CAN bus.

Check:
– The ISO CAN bus network.
– The external function module EXT (A62).

Id7887h

EXT (A62)

The ISO CAN bus
component of the EXT
module is faulty.

Check:
– The ISO CAN bus network.
– The external function module EXT (A62).

Id7888h

EXT (A62)

Short-circuit to ground of the
left indicator information.

Check:
– The indicator switch (S16).
– The external function module EXT (A62).

Id7889h

EXT (A62)

Short-circuit to ground of the
right indicator information.

Check:
– The indicator switch (S16).
– The external function module EXT (A62).

Id788Ah

EXT (A62)

The EXT external function
module has not received
actual speed information for
more than 5 seconds (BUS
CAN).

The actual speed information is
not available on the 7-pin ISO
connector.

Check:
– The CLAAS vehicle CAN bus network.
– The bus CAN network communication
module BDG (A103).
– The instrument panel module DBD (A101).
– The external function module EXT (A62).

Id788Bh

EXT (A62)

The EXT external function
module has not received
theoretical speed information
for over 5 seconds (BUS
CAN).

The theroretical speed
information is not available on
the 7-pin ISO connector.

Check:
– The CLAAS vehicle CAN bus network.
– The bus CAN network communication
module BDG (A103).
– The instrument panel module DBD (A101).
– The external function module EXT (A62).

Id788Ch

EXT (A62)

The EXT external function
module has not received
speed information from the
rear PTO for more than 5
seconds (BUS CAN).

The PTO speed information is
not available over the 7-pin ISO
connector.

Check:
– The CLAAS vehicle CAN bus network.
– The bus CAN network communication
module BDG (A103).
– The TR3 transmission module (A57-3).
– The external function module EXT (A62).

Id788Dh

EXT (A62)

The EXT external function
module has not received the
rear lifting status information
for more than 5 seconds
(BUS CAN).

The lifting high position
informationis not available on
the 7-pin ISO connector.

Check:
– The CLAAS vehicle CAN bus network.
– The bus CAN network communication
module BDG (A103).
– The lifting module REH (A58).
– The external function module EXT (A62).

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id788Eh

EXT (A62)

The EXT external function
module has not received rear
lifting position information for
more than 5 seconds (BUS
CAN).

The lifting position information
is not available over the 7-pin
ISO connector.

Check:
– The CLAAS vehicle CAN bus network.
– The bus CAN network communication
module BDG (A103).
– The lifting module REH (A58).
– The external function module EXT (A62).

Id788Fh

EXT (A62)

The EXT external function
module has not received the
rear lifting, theoretical speed
and rear PTO information for
more than 5 seconds (BUS
CAN).

No information is available over
the 7-pin ISO connector.

Check:
– The CLAAS vehicle CAN bus network.
– The bus CAN network communication
module BDG (A103).
– The lifting module REH (A58).
– The instrument panel module DBD (A101).
– The TR3 transmission module (A57-3).
– The external function module EXT (A62).

Id7890h

EXT (A62)

The external function module
EXT has received no
information from the engine
or receives an invalid engine
speed signal for more than 5
seconds (Bus CAN).

The engine speed information is
not available on the 7 pin ISO
connector.

Check:
– The CLAAS vehicle CAN bus network.
– The bus CAN network communication
module BDG (A103).
– The ENG (A15) module.
– The external function module EXT (A62).

Id7891h

EXT (A62)

The external function module
EXT has received no
information from the position
lights or receives an invalid
signal from the position lights
for more than 5 seconds
(BUS CAN).

The position light information is
not available on the ISO 7 pin
connector.

Check:
– The CLAAS vehicle CAN bus network.
– CAN bus network communication module.

Id7892h

EXT (A62)

The external function module
EXT has received no
information from the stop
lights or receives an invalid
signal from the left stop light
for more than 5 seconds
(Bus CAN).

The left stop light information is
not available on the 7 pin ISO
connector.

Check:
– The CLAAS vehicle CAN bus network.
– CAN bus network communication module.

Id7893h

EXT (A62)

The external function module
EXT has received no
information from the stop
lights or receives an invalid
signal from the right stop light
for more than 5 seconds
(Bus CAN).

The right stop light information
is not available on the 7 pin ISO
connector.

Check:
– The CLAAS vehicle CAN bus network.
– CAN bus network communication module.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7894h

EXT (A62)

The external function module
EXT receives invalid
information from the WLP
(A104) modules for more
than 5 seconds (Bus CAN).

The information from the WLP
is not available on the 7 pin ISO
connector.

Check:
– The CLAAS vehicle CAN bus network.
– CAN bus network communication module.

Id7895h

EXT (A62)

The external function module
EXT receives invalid rear
power take-off engaging
information for more than 5
seconds (Bus CAN).

The rear power take-off
engaging information is not
available on the 7 pin ISO
connector

Check:
– The CLAAS vehicle CAN bus network.
– CAN bus network communication module.

Id78A0h

EXT (A62)

You are about to launch a
sequence CSM.

Id78A1h

EXT (A62)

The CSM sequence is
interrupted.

CSM sequence interrupted as
ignition off

Id78A2h

EXT (A62)

The CSM sequence cannot
be started.

The CSM sequence does not
start as speed is not high
enough.

Speed must exceed 1,5 km/h

Id78A3h

EXT (A62)

The version of the CSM
sequence is not compatible.

The sequence has been
cleared.

Id78A4h

EXT (A62)

Fault of the "Claas Sequence
Management" (S177) switch.

Check:
– The "Claas Sequence Management" (S177)
switch
– The external function module EXT (A62)
– The hydraulic module HYD (A60)

Id78A5h

EXT (A62)

Switch the CSM (S177)
switch to play before
selecting a sequence.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id78A6h

EXT (A62)

The CSM sequence is
interrupted.

The CSM sequence is
interrupted after pressing one of
the external commands.

Id78A7h

EXT (A62)

The CSM sequence is
interrupted.

The CSM sequence is
interrupted as the driver is not
sitting on the seat.

Id78A8h

EXT (A62)

The CSM sequence is
interrupted.

The CSM sequence does not
start as speed is not high
enough.

Speed must exceed 1,5 km/h

Id78A9h

EXT (A62)

The CSM sequence is
interrupted.

The CSM sequence is
interrupted as the engine is not
running.

Id78AAh

EXT (A62)

One of the functions to be
controlled by the CSM is
beyond its control without
prior information to the EXT
(A62) external function
module.

Entry rejected

Check:
– The HYD (A60) module, Electrical wiring,
Valve
– The external function module EXT (A62)

Id78ABh

EXT (A62)

Communication problem
between one of the functions
to be controlled by the CSM
and the EXT (A62) external
function module.

No response after validation.

Check:
– The HYD (A60) module, Electrical wiring,
Valve
– The external function module EXT (A62)

Id78ACh

EXT (A62)

Communication problem
between one of the functions
to be controlled by the CSM
and the EXT (A62) external
function module.

No input message received.

Check:
– The HYD (A60) module, Electrical wiring,
Valve
– The external function module EXT (A62)

Id78ADh

EXT (A62)

Recording of the CSM
sequence is interrupted.

Memory full.

Recording canceled.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id78AEh

EXT (A62)

The EXT (A62) external
function module detects an
inconsistency between 2
signals, the first giving the
status of the CSM function,
the second the status of the
"Claas Sequence
Management" (S177) switch.

Check:
– The "Claas Sequence Management" (S177)
switch
– The external function module EXT (A62)

Id78AFh

EXT (A62)

The CSM sequence cannot
be started.

Cannot display the sequence.

Id78C6h

EXT (A62)

The CSM sequence cannot
be started.

No recorded sequence is valid.

Id78C7h

EXT (A62)

The CAN "Distance"
message is not received by
the EXT (A62) external
function module.

Check:
– The DBD (A101) dashboard sending the
information to the CAN and the bus CAN
BDG (A103) network communication
module relaying it to the Claas Vehicle Can
Bus.

Id78C8h

EXT (A62)

Internal error CSM.

Id78C9h

EXT (A62)

No CSM sequence can be
read or recorded.

The engine is not running.

Id78CAh

EXT (A62)

No CSM sequence can be
read or recorded.

The driver is not sitting on the
seat.

Id78CBh

EXT (A62)

No CSM sequence can be
read or recorded.

Ignition switched off.

Id78CCh

EXT (A62)

No CSM sequence can be
read or recorded.

Speed exceeds 20 km/h

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

Id78D1h

EXT (A62)

The CAN "Engine running"
message is not received by
the external function module
EXT (A62) or invalid value.

Check:
– The TR2 transmission module (A57-2).
– The Bus CAN network communication
module BDG (A103)
– The external function module EXT (A62).

Id78D2h

EXT (A62)

The CAN "Driver sitting"
message is not received by
the EXT (A62) external
function module or invalid
value.

Check:
– The TR2 transmission module (A57-2).
– The Bus CAN network communication
module BDG (A103)
– The external function module EXT (A62).

Id78D3h

EXT (A62)

The CAN "Ignition off"
message is not received by
the external function module
EXT (A62) or invalid value.

Check:
– The lifting module REH (A58)
– The Bus CAN network communication
module BDG (A103)
– The external function module EXT (A62).

Id78D4h

EXT (A62)

The CAN "Contacts S1 or
S2" message is not received
by the EXT (A62) external
function module or invalid
value.

Check:
– The MFA (A100) armrest multifunction
module
– The external function module EXT (A62).

Id78D5h

EXT (A62)

The CAN "Stop contact"
message is not received by
the external function module
EXT (A62) or invalid value.

Check:
– The MFA (A100) armrest multifunction
module
– The external function module EXT (A62).

Id78D6h

EXT (A62)

The CAN "CSM permission"
message is not received by
the external function module
EXT (A62) or invalid value.

Check:
– The hydraulic module HYD (A60)
– The external function module EXT (A62).

Id78D7h

EXT (A62)

The CSM sequence cannot
be started.

Speed exceeds 20 km/h

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id78D8h

EXT (A62)

The CAN "Speed" message
is not received by the
external function module
EXT (A62) or invalid value.

Check:
– The speed sensor (GPS, radar, wheels)
– The DBD (A101) dashboard sending the
information to the CAN and the Bus CAN
BDG (A103) network communication
module relaying it to the Claas vehicle CAN
Bus.

Id78D9h

EXT (A62)

Sequence recording aborted.

Id78DAh

EXT (A62)

The CSM sequence cannot
be started.

Battery voltage too low.

Id78DBh

EXT (A62)

The CSM sequence is
interrupted.

The CSM sequence is
interrupted as it uses an
unknown function.

Id78DCh

EXT (A62)

The CSM sequence cannot
be started.

Type of machine incorrect.

Error code

Native
code

Sender
module

Designation

Cause/System response

Comment/Solution

 

DBD (A101)

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

Id7F00h

DBD (A101)

Confirmation of engine speed
memorization

Id7F01h

DBD (A101)

Communication error between
the SFA module and the DBD

No message received from the SFA
(A102) module for more than 5s.

Back to normal mode when the message is
received again

Id7F02h

DBD (A101)

Communication error between
the HYD module and the DBD

No message received from the
HYD (A60) module for more than
5s.

Back to normal mode when the message is
received again

Id7F03h

DBD (A101)

Communication error between
the EXT module and the DBD

No message received from the
EXT (A62) module for more than
5s.

Back to normal mode when the message is
received again

Id7F04h

DBD (A101)

Communication error between
the SCU module and the DBD

No message received from the
SCU (A131) module for more than
5s.

Back to normal mode when the message is
received again

Id7F05h

DBD (A101)

Communication error between
the C-Matic and the

No message received from the
C Matic for more than 5s.

Back to normal mode when the message is
received again

Id7F06h

DBD (A101)

Communication error between
the MFT module and the DBD

No message received from the
MFT (A30) module for more than
5s.

Back to normal mode when the message is
received again

Id7F07h

DBD (A101)

Communication error between
the WLP module and the DBD

No message received from the
WLP (A104) module for more than
5s.

Back to normal mode when the message is
received again

Id7F08h

DBD (A101)

Communication error between
the MFA module and the DBD

No message received from the
MFA (A100) module for more than
5s.

Back to normal mode when the message is
received again

Id7F09h

DBD (A101)

Communication error

No message received from the
DBD (A101) module for more than
5s.

Back to normal mode when the message is
received again

Id7F0Ah

DBD (A101)

Communication error between
the ENG module and the DBD

No message received from the
ENG (A15) module for more than
5s.

Back to normal mode when the message is
received again

Id7F0Bh

DBD (A101)

Communication error between
the TR1 module and the DBD

No message received from the TR1
(A57-1) module for more than 5s.

Back to normal mode when the message is
received again

Id7F0Ch

DBD (A101)

Communication error between
the TR2 module and the DBD

No message received from the TR2
(A57-2) module for more than 5s.

Back to normal mode when the message is
received again

Id7F0Dh

DBD (A101)

Communication error between
the TR3 module and the DBD

No message received from the TR3
(A57-3) module for more than 5s.

Back to normal mode when the message is
received again

 

 

Id7F0Eh

DBD (A101)

Communication error between
the REH module and the DBD

No message received from the
REH (A58) module for more than
5s.

Back to normal mode when the message is
received again

Id7F0Fh

DBD (A101)

Bridge transmission error over
the CLAAS CAN Bus network

Short-circuit on the supply of the
CLAAS CAN Bus

The tractor returns to the normal mode when
the error disappears

Id7F10h

DBD (A101)

Too much bridge data over the
CLAAS CAN Bus network

CLAAS CAN Bus short-circuited to
ground

The tractor returns to the normal mode
when the error disappears

Id7F11h

DBD (A101)

The bridge has disconnected
from the CLAAS CAN Bus
network

No message can be transmitted
until the module is back online

The tractor returns to the normal mode
when the error disappears

Id7F12h

DBD (A101)

Bridge transmission error over
the J1939 CAN Bus network

Short-circuit on the supply of the
J1939 CAN Bus

The tractor returns to the normal mode
when the error disappears

Id7F13h

DBD (A101)

Too much bridge data over the
J1939 CAN Bus network

J1939 CAN Bus short-circuited to
ground

The tractor returns to the normal mode
when the error disappears

Id7F14h

DBD (A101)

The bridge has disconnected
from the J1939 CAN Bus
network

No message can be transmitted
until the module is back online

The tractor returns to the normal mode
once the module is online again.

Id7F2Dh

DBD (A101)

Theoretical speed sensor
(B227) Disconnected

The harness giving the information
of the (B227) speed sensor
between the TR1 module and the
DBD
is probably damaged

Check the harness between the TR1 (A57-1)
module and the DBD (A101).

Id7F2Eh

DBD (A101)

The engine speed sensor
(B228) Disconnected

The tractor returns to the normal mode
when the error disappears

Id7F2Fh

DBD (A101)

Real speed sensor
(radar)(B230) not connected.

Antislip control can no longer be
used.

The tractor returns to the normal mode
when the error disappears

Id7F30h

DBD (A101)

The rear PTO speed sensor
(B142) Disconnected

The tractor returns to the normal mode
when the error disappears

Id7F31h

DBD (A101)

The module's interface is not
connected

Cannot browse the menus.

The tractor returns to the normal mode
when the error disappears

Id7F32h

DBD (A101)

Fuel level potentiometer (R35)
not connected.

No information on consumption and
time before refuelling available

The tractor returns to the normal mode
when the error disappears

Id7F33h

DBD (A101)

(B45) coolant temperature
sensor Disconnected

The tractor returns to the normal mode
when the error disappears

Id7F34h

DBD (A101)

Air filter blocked

Air filter blocked

Clean air filter.
Check the (Z69) air filter clogged contact.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Id7F35h

DBD (A101)

Transmission oil filter clogged.

Transmission oil filter clogged.

Clean the oil filter.
Check the (Z102) oil filter clogging contact.

Id7F36h

DBD (A101)

Alarm Trailer brake

Id7F37h

DBD (A101)

Engine controller disconnected
during CSM sequence.

Engine controller locked.
The engine controller is inoperative

After 20 seconds, the tractor initializes, then
the sequence is relaunched If nothing
happens, reset the CSM

Id7F38h

DBD (A101)

Engine controller disconnected
during CSM sequence.

Communication error with the
engine controller.
The engine controller is inoperative

After 20 seconds, the tractor initializes, then
the sequence is relaunched
If nothing happens, reset the CSM

Id7F39h

DBD (A101)

Functions unavailable

Back to normal mode when the message is
received again

 

Id7F3Ah

DBD (A101)

Message missing on the level of
button 1 and 2 in the CSM
sequence

Functions unavailable

Back to normal mode when the message is
received again

Id7F3Bh

DBD (A101)

Message missing on the level of
the front external control buttons

Functions unavailable

Back to normal mode when the message is
received again

Id7F3Ch

DBD (A101)

Message missing on the level of
the function 1 and 2 button

Functions unavailable

Back to normal mode when the message is
received again

Id7F3Dh

DBD (A101)

Message missing on the level of
the function 3 and 4 button

Functions unavailable

Back to normal mode when the message is
received again

Id7F3Eh

DBD (A101)

Message missing on the level of
the ITE

No message from the ITE during 5
seconds

Back to normal mode when the message is
received again

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

HYD PVV (A60)

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

IdA000h

0

HYD (A60)

Error during the RAM test at
start.

RAM faulty.
Valve 1 returns to neutral.

The RAM memory of the 1 valve is write/
read tested when starting.
Clear the error
If the error appears again replace the 1
valve.

IdA001h

1

HYD (A60)

Error upon initial commissioning
of the valve.

Faulty EEPROM.
Valve 1 returns to neutral.

This error should not occur during work, as it
appears during the initial commissioning.

IdA002h

3

HYD (A60)

Division by 0 internal error.

Valve 1 returns to neutral.

The calculator cannot divide by 0.
Clear the error.
If the error appears again, replace the 1
valve.

IdA003h

4

HYD (A60)

Internal calculation error.

Value out of range.
Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA004h

5

HYD (A60)

Internal calculation error.

Value out of range.
Valve 1 returns to neutral.

Clear the error
If the error appears again replace the 1
valve.

IdA005h

6

HYD (A60)

Error when saving the
parameters.

Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA006h

8

HYD (A60)

Spool behaviour error.

Error between the position
requested and the controlled
position of the 1 valve spool.
Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA00Bh

16

HYD (A60)

Error when saving the
parameters in the EEPROM.

Memory problem.
Valve 1 returns to neutral.

Switch the ignition off and wait at least 20
seconds

IdA00Ch

17

HYD (A60)

Error when setting the valve.

The 1 valve is configured
improperly.
Back to previous parameter.

This error may appear when changing an
address or a parameter in the 1 valve.
If the error appears again, replace the 1
valve.

 

 

IdA00Dh

18

HYD (A60)

Flash memory error.

Error between the original
programme and the current
programme.
Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA00Eh

19

HYD (A60)

Spool position supervision error.

The actual position of the spool is
too far from the position controlled
by the programme.
Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA00Fh

20

HYD (A60)

Short-circuit on the level of the 1
valve position controller

The system providing control of the
1 valve position is damaged or
short-circuited

Clear the error
If the error appears again,

IdA010h

21

HYD (A60)

Supply of the 1 valve above max
value.

Check the voltage delivered by the
alternator and battery.
Clear the error
If the error appears again, replace the 1
valve.

IdA011h

22

HYD (A60)

Supply of the 1 valve below the
min value.

Check the voltage delivered by the
alternator and battery.
Clear the error
If the error appears again, replace the 1 valve.

IdA012h

23

HYD (A60)

No response from the
microcontroller.

Supervisor damaged.
Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA013h

24

HYD (A60)

Supervisor error when starting.

Supervisor not started upon tractor
starting.
Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA014h

HYD (A60)

The spool of the 1 valve does
not reach the position requested
within the time set.

IdA015h

26

HYD (A60)

The 1 valve does not return to
neutral.

The 1 valve has not returned to
neutral within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 1 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 1
valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA016h

27

HYD (A60)

The 1 valve does not reach the
float position.

The 1 valve does not reach the
float position within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 1 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 1
valve.

IdA017h

28

HYD (A60)

The 1 valve is not at neutral
when starting.

Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA018h

29

HYD (A60)

The 1 valve is not at the position
desired.

The valve spool was pushed too far
in respect of the position desired.

Clear the error
If the error appears again, replace the 1 valve.

IdA019h

30

HYD (A60)

Problem controlling the 1 valve.

The drawer moves in the wrong
direction in respect of the
command.

Clear the error
If the error appears again, replace the 1 valve.

IdA01Bh

32

HYD (A60)

The timeout without
commanding the 1 valve has
expired.

The 1 valve is in the neutral
position as it has not been
commanded for a certain time.

IdA025h

42

HYD (A60)

Value of the 1 valve command
impossible.

Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA026h

43

HYD (A60)

Value of the 1 valve command
impossible.

Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA027h

44

HYD (A60)

Value of the 1 valve command
impossible.

Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA028h

45

HYD (A60)

Value of the 1 valve command
impossible.

Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA029h

46

HYD (A60)

Value of the 1 valve command
impossible.

Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

IdA02Ah

47

HYD (A60)

Value of the 1 valve command
impossible.

Valve 1 returns to neutral.

Clear the error
If the error appears again, replace the 1 valve.

IdA02Bh

0

HYD (A60)

Error during the RAM test at
start.

RAM faulty.
Valve 2 returns to neutral.

The RAM memory of the 1 valve is write/read
tested when starting.
Clear the error
If the error appears again, replace the 2 valve.

IdA02Ch

1

HYD (A60)

Error upon initial commissioning
of the valve.

Faulty EEPROM.
Valve 2 returns to neutral.

This error should not occur during work,
as it appears during the initial
commissioning.

IdA02Dh

3

HYD (A60)

Division by 0 internal error.

Valve 2 returns to neutral.

The calculator cannot divide by 0.
Clear the error
If the error appears again, replace the 2 valve.

IdA02Eh

4

HYD (A60)

Internal calculation error.

Value out of range.
Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA02Fh

5

HYD (A60)

Internal calculation error.

Value out of range.
Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA30h

6

HYD (A60)

Error when saving the
parameters.

Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA031h

8

HYD (A60)

Spool behaviour error.

Error between the position
requested and the controlled
position of the 2 valve spool.
Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA036h

16

HYD (A60)

Error when saving the
parameters in the EEPROM.

Memory problem.
Valve 2 returns to neutral.

Switch the ignition off and wait at least 20
seconds
If the error appears again, replace the 2 valve.

IdA037h

17

HYD (A60)

Error when setting the valve.

The 2 valve is configured
improperly.
Back to previous parameter.

This error may appear when changing an
address or a parameter in the 2 valve.
Reconfigure.
If the error appears again, replace the 2 valve.

IdA038h

18

HYD (A60)

Flash memory error.

Error between the original
programme and the current
programme.
Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA039h

19

HYD (A60)

Spool position supervision error.

The actual position of the spool is
too far from the position controlled
by the programme.
Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA03Ah

20

HYD (A60)

Short-circuit on the level of the 2
valve position controller

The system providing control of the
2 valve position is damaged or
short-circuited
Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA03Bh

21

HYD (A60)

Supply of the 2 valve above max
value.

Check the voltage delivered by the alternator
and battery.

IdA03Ch

22

HYD (A60)

Supply of the 2 valve below the
min value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 2 valve.

IdA03Dh

23

HYD (A60)

No response from the
microcontroller.

Supervisor damaged.
Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA03Eh

24

HYD (A60)

Supervisor error when starting.

Supervisor error when starting.
Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA03Fh

HYD (A60)

The spool of the 2 valve does
not reach the position requested
within the time set.

IdA040h

26

HYD (A60)

The 2 valve does not return to
neutral.

The 2 valve has not returned to
neutral within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 2 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 2 valve.

IdA041h

27

HYD (A60)

The 2 valve does not reach the
float position.

The 2 valve does not reach the
float position within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 2 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 2 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA042h

28

HYD (A60)

The 2 valve is not at neutral
when starting.

Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA043h

29

HYD (A60)

The 2 valve is not at the position
desired.

The valve spool was pushed too far
in respect of the position desired.
Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA044h

30

HYD (A60)

Problem controlling the 2 valve.

The drawer moves in the wrong
direction in respect of the
command.
Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA046h

32

HYD (A60)

The timeout without
commanding the 2 valve has
expired.

The 2 valve is in the neutral
position as it has not been
commanded for a certain time.

IdA050h

42

HYD (A60)

Value of the 2 valve command
impossible.

Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA051h

43

HYD (A60)

Value of the 2 valve command
impossible.

Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA052h

44

HYD (A60)

Value of the 2 valve command
impossible.

Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA053h

45

HYD (A60)

Value of the 2 valve command
impossible.

Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA054h

46

HYD (A60)

Value of the 2 valve command
impossible.

Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA055h

47

HYD (A60)

Value of the 2 valve command
impossible.

Valve 2 returns to neutral.

Clear the error
If the error appears again, replace the 2 valve.

IdA056h

0

HYD (A60)

Error during the RAM test at
start.

RAM faulty.
Valve 3 returns to neutral.

The RAM memory of the 1 valve is write/read
tested when starting.
Clear the error
If the error appears again, replace the 3 valve.

IdA057h

1

HYD (A60)

Error upon initial commissioning
of the valve.

Faulty EEPROM.
Valve 3 returns to neutral.

This error should not occur during work, as it
appears during the initial commissioning.

IdA058h

3

HYD (A60)

Division by 0 internal error.

Valve 3 returns to neutral.

The calculator cannot divide by 0.
Clear the error
If the error appears again, replace the 3 valve.

IdA059h

4

HYD (A60)

Internal calculation error.

Value out of range.
Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

IdA069h

24

HYD (A60)

Supervisor error when starting.

Supervisor not started upon tractor
starting.
Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

IdA06Ah

HYD (A60)

The spool of the 3 valve does
not reach the position requested
within the time set.

IdA06Bh

26

HYD (A60)

The 3 valve does not return to
neutral.

The 3 valve has not returned to
neutral within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 3 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 3 valve.

IdA06Ch

27

HYD (A60)

The 3 valve does not reach the
float position.

The 3 valve does not reach the
float position within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 3 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 3 valve.

IdA06Dh

28

HYD (A60)

The 3 valve is not at neutral
when starting.

Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

IdA06Eh

29

HYD (A60)

The 3 valve is not at the position
desired.

The valve spool was pushed too far
in respect of the position desired.
Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

IdA06Fh

30

HYD (A60)

Problem controlling the 3 valve.

The drawer moves in the wrong
direction in respect of the
command.
Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

IdA071h

32

HYD (A60)

The timeout without
commanding the 3 valve has
expired.

The 3 valve is in the neutral
position as it has not been
commanded for a certain time.

IdA07Bh

42

HYD (A60)

Value of the 3 valve command
impossible.

Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

IdA07Ch

43

HYD (A60)

Value of the 3 valve command
impossible.

Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

IdA07Dh

44

HYD (A60)

Value of the 3 valve command
impossible.

Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA07Eh

45

HYD (A60)

Value of the 3 valve command
impossible.

Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

IdA07Fh

46

HYD (A60)

Value of the 3 valve command
impossible.

Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

IdA080h

47

HYD (A60)

Value of the 3 valve command
impossible.

Valve 3 returns to neutral.

Clear the error
If the error appears again, replace the 3 valve.

IdA081h

0

HYD (A60)

Error during the RAM test at
start.

RAM faulty.
Valve 4 returns to neutral.

The RAM memory of the 1 valve is write/read
tested when starting.
Clear the error
If the error appears again, replace the 4 valve.

IdA082h

1

HYD (A60)

Error upon initial commissioning
of the valve.

Faulty EEPROM.
Valve 4 returns to neutral.

This error should not occur during work, as it
appears during the initial commissioning.

IdA083h

3

HYD (A60)

Division by 0 internal error.

Valve 4 returns to neutral.

The calculator cannot divide by 0.
Clear the error
If the error appears again, replace the 4 valve.

IdA084h

4

HYD (A60)

Internal calculation error.

Value out of range.
Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA085h

5

HYD (A60)

Internal calculation error.

Value out of range.
Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA086h

6

HYD (A60)

Error when saving the
parameters.

Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA087h

8

HYD (A60)

Spool behaviour error.

Error between the position
requested and the controlled
position of the 4 valve spool.
Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA08Ch

16

HYD (A60)

Error when saving the
parameters in the EEPROM.

Memory problem.
Valve 4 returns to neutral.

Switch the ignition off and wait at least 20
seconds
If the error appears again, replace the 4 valve.

IdA08Dh

17

HYD (A60)

Error when setting the valve.

The 4 valve is configured
improperly.
Back to previous parameter.

This error may appear when changing an
address or a parameter in the 4 valve.
Reconfigure.
If the error appears again, replace the 4 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA08Eh

18

HYD (A60)

Flash memory error.

Error between the original
programme and the current
programme.
Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA08Fh

19

HYD (A60)

Spool position supervision error.

The actual position of the spool is
too far from the position controlled
by the programme.
Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA090h

20

HYD (A60)

Short-circuit on the level of the 4
valve position controller

The system providing control of the
4 valve position is damaged or
short-circuited
Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA091h

21

HYD (A60)

Supply of the 4 valve above max
value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 4 valve.

IdA092h

22

HYD (A60)

Supply of the 4 valve below the
min value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 4 valve.

IdA093h

23

HYD (A60)

No response from the
microcontroller.

Supervisor damaged.
Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA094h

24

HYD (A60)

Supervisor error when starting.

Supervisor not started upon tractor
starting.
Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA095h

HYD (A60)

The spool of the 4 valve does
not reach the position requested
within the time set.

IdA096h

26

HYD (A60)

The 4 valve does not return to
neutral.

The 4 valve has not returned to
neutral within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 4 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 4 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

IdA097h

27

HYD (A60)

The 4 valve does not reach the
float position.

The 4 valve does not reach the
float position within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 4 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 4 valve.

IdA098h

28

HYD (A60)

The 4 valve is not at neutral
when starting.

Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA099h

29

HYD (A60)

The 4 valve is not at the position
desired.

The valve spool was pushed too far
in respect of the position desired.
Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA09Ah

30

HYD (A60)

Problem controlling the 4 valve.

The drawer moves in the wrong
direction in respect of the
command.
Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA09Ch

32

HYD (A60)

The timeout without
commanding the 4 valve has
expired.

The 4 valve is in the neutral
position as it has not been
commanded for a certain time.

IdA0A6h

42

HYD (A60)

Value of the 4 valve command
impossible.

Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA0A7h

43

HYD (A60)

Value of the 4 valve command
impossible.

Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA0A8h

44

HYD (A60)

Value of the 4 valve command
impossible.

Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA0A9h

45

HYD (A60)

Value of the 4 valve command
impossible.

Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA0AAh

46

HYD (A60)

Value of the 4 valve command
impossible.

Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA0ABh

47

HYD (A60)

Value of the 4 valve command
impossible.

Valve 4 returns to neutral.

Clear the error
If the error appears again, replace the 4 valve.

IdA0ACh

0

HYD (A60)

Error during the RAM test at
start.

RAM faulty.
Valve 5 returns to neutral.

The RAM memory of the 1 valve is write/read
tested when starting.
Clear the error
If the error appears again, replace the 5 valve.

IdA0ADh

1

HYD (A60)

Error upon initial commissioning
of the valve.

Faulty EEPROM.
Valve 5 returns to neutral.

This error should not occur during work, as it
appears during the initial commissioning.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA0AEh

3

HYD (A60)

Division by 0 internal error.

Valve 5 returns to neutral.

The calculator cannot divide by 0.
Clear the error
If the error appears again, replace the 5 valve.

IdA0AFh

4

HYD (A60)

Internal calculation error..

Value out of range.
Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0B0h

5

HYD (A60)

Internal calculation error..

Value out of range.
Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0B1h

6

HYD (A60)

Error when saving the
parameters.

Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0B2h

8

HYD (A60)

Spool behaviour error.

Error between the position
requested and the controlled
position of the 5 valve spool.
Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0B7h

16

HYD (A60)

Error when saving the
parameters in the EEPROM.

Memory problem.
Valve 5 returns to neutral.

Switch the ignition off and wait at least 20
seconds
If the error appears again, replace the 5 valve.

IdA0B8h

17

HYD (A60)

Error when setting the valve.

The 5 valve is configured
improperly.
Back to previous parameter.

This error may appear when changing an
address or a parameter in the 5 valve.
Reconfigure.
If the error appears again, replace the 5 valve.

IdA0B9h

18

HYD (A60)

Flash memory error.

Error between the original
programme and the current
programme.
Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0BAh

19

HYD (A60)

Spool position supervision error.

The actual position of the spool is
too far from the position controlled
by the programme.
Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0BBh

20

HYD (A60)

Short-circuit on the level of the 5
valve position controller

The system providing control of the
5 valve position is damaged or
short-circuited
Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0BCh

21

HYD (A60)

Supply of the 5 valve above max
value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 5 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

IdA0BDh

22

HYD (A60)

Supply of the 5 valve below the
min value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 5 valve.

IdA0BEh

23

HYD (A60)

No response from the
microcontroller.

Supervisor damaged.
Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0BFh

24

HYD (A60)

Supervisor error when starting.

Supervisor not started upon tractor
starting.
Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0C0h

HYD (A60)

The spool of the 5 valve does
not reach the position requested
within the time set.

IdA0C1h

26

HYD (A60)

The 5 valve does not return to
neutral.

The 5 valve has not returned to
neutral within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 5 returns to neutral.

Let the tractor warm up and test again.
Clear the error
If the error appears again, replace the 5 valve.

IdA0C2h

27

HYD (A60)

The 5 valve does not reach the
float position.

The 5 valve does not reach the
float position within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 5 returns to neutral.

Let the tractor warm up and test again.
Clear the error
If the error appears again, replace the 5 valve.

IdA0C3h

28

HYD (A60)

The 5 valve is not at neutral
when starting.

Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0C4h

29

HYD (A60)

The 5 valve is not at the position
desired.

The valve spool was pushed too far
in respect of the position desired.
Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0C5h

30

HYD (A60)

Problem controlling the 5 valve.

The drawer moves in the wrong
direction in respect of the
command.
Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA0C7h

32

HYD (A60)

The timeout without
commanding the 5 valve has
expired.

The 5 valve is in the neutral
position as it has not been
commanded for a certain time.

IdA0D1h

42

HYD (A60)

Value of the 5 valve command
impossible.

Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0D2h

43

HYD (A60)

Value of the 5 valve command
impossible.

Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0D3h

44

HYD (A60)

Value of the 5 valve command
impossible.

Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0D4h

45

HYD (A60)

Value of the 5 valve command
impossible.

Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0D5h

46

HYD (A60)

Value of the 5 valve command
impossible.

Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0D6h

47

HYD (A60)

Value of the 5 valve command
impossible.

Valve 5 returns to neutral.

Clear the error
If the error appears again, replace the 5 valve.

IdA0D7h

0

HYD (A60)

Error during the RAM test at
start.

RAM faulty.
Valve 6 returns to neutral.

The RAM memory of the 1 valve is write/read
tested when starting.
Clear the error
If the error appears again, replace the 6 valve.

IdA0D8h

1

HYD (A60)

Error upon initial commissioning
of the valve.

Faulty EEPROM.
Valve 6 returns to neutral.

This error should not occur during work, as it
appears during the initial commissioning.

IdA0D9h

3

HYD (A60)

Division by 0 internal error.

Valve 6 returns to neutral.

The calculator cannot divide by 0.
Clear the error
If the error appears again, replace the 6 valve.

IdA0DAh

4

HYD (A60)

Internal calculation error..

Value out of range.
Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0DBh

5

HYD (A60)

Internal calculation error..

Value out of range.
Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0DCh

6

HYD (A60)

Error when saving the
parameters..

Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0DDh

8

HYD (A60)

Spool behaviour error.

Error between the position
requested and the controlled
position of the 6 valve spool.
Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA0E2h

16

HYD (A60)

Error when saving the
parameters in the EEPROM.

Memory problem.
Valve 6 returns to neutral.

Switch the ignition off and wait at least 20
seconds
If the error appears again, replace the 6 valve.

IdA0E3h

17

HYD (A60)

Error when setting the valve.

The 6 valve is configured
improperly.
Back to previous parameter.

This error may appear when changing an
address or a parameter in the 6 valve.
Reconfigure.
If the error appears again, replace the 6 valve.

IdA0E4h

18

HYD (A60)

Flash memory error.

Error between the original
programme and the current
programme.
Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0E5h

19

HYD (A60)

Spool position supervision error.

The actual position of the spool is
too far from the position controlled
by the programme.
Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0E6h

20

HYD (A60)

Short-circuit on the level of the 6
valve position controller

The system providing control of the
6 valve position is damaged or
short-circuited
Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0E7h

21

HYD (A60)

Supply of the 6 valve above max
value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 6 valve.

IdA0E8h

22

HYD (A60)

Supply of the 6 valve below the
min value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 6 valve.

IdA0E9h

23

HYD (A60)

No response from the
microcontroller.

Supervisor damaged.
Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0EAh

24

HYD (A60)

Supervisor error when starting.

Supervisor not started upon tractor
starting.
Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0EBh

HYD (A60)

The spool of the 6 valve does
not reach the position requested
within the time set.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

IdA0ECh

26

HYD (A60)

The 6 valve does not return to
neutral.

The 6 valve has not returned to
neutral within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 6 returns to neutral.

Let the tractor warm up and test again.
Clear the error
If the error appears again, replace the 6 valve.

IdA0EDh

27

HYD (A60)

The 6 valve does not reach the
float position.

The 6 valve does not reach the
float position within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 6 returns to neutral.

Let the tractor warm up and test again.
Clear the error
If the error appears again, replace the 6 valve.

IdA0EEh

28

HYD (A60)

The 6 valve is not at neutral
when starting.

Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0EFh

29

HYD (A60)

The 6 valve is not at the position
desired.

The valve spool was pushed too far
in respect of the position desired.
Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0F0h

30

HYD (A60)

Problem controlling the 6 valve.

The drawer moves in the wrong
direction in respect of the
command.
Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0F2h

32

HYD (A60)

The timeout without
commanding the 6 valve has
expired.

The 6 valve is in the neutral
position as it has not been
commanded for a certain time.

IdA0FCh

42

HYD (A60)

Value of the 6 valve command
impossible.

Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0FDh

43

HYD (A60)

Value of the 6 valve command
impossible.

Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0FEh

44

HYD (A60)

Value of the 6 valve command
impossible.

Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA0FFh

45

HYD (A60)

Value of the 6 valve command
impossible.

Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA100h

46

HYD (A60)

Value of the 6 valve command
impossible.

Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

IdA101h

47

HYD (A60)

Value of the 6 valve command
impossible.

Valve 6 returns to neutral.

Clear the error
If the error appears again, replace the 6 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA102h

0

HYD (A60)

Error during the RAM test at
start.

RAM faulty.
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA103h

1

HYD (A60)

Error upon initial commissioning
of the valve.

Faulty EEPROM.
Valve 7 returns to neutral.

This error should not occur during work, as it
appears during the initial commissioning.

IdA104h

3

HYD (A60)

Division by 0 internal error.

Valve 7 returns to neutral.

The calculator cannot divide by 0.
Clear the error
If the error appears again, replace the 7 valve.

IdA105h

4

HYD (A60)

Internal calculation error.

Value out of range.
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA106h

5

HYD (A60)

Internal calculation error.

Value out of range.
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA107h

6

HYD (A60)

Error when saving the
parameters.

Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA108h

8

HYD (A60)

Spool behaviour error.

Error between the position
requested and the controlled
position of the 7 valve spool.
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA10Dh

16

HYD (A60)

Error when saving the
parameters in the EEPROM.

Memory problem.
Valve 7 returns to neutral.

Switch the ignition off and wait at least 20
seconds
If the error appears again, replace the 7 valve.

IdA10Eh

17

HYD (A60)

Error when setting the valve.

The 7 valve is configured
improperly.
Back to previous parameter.

This error may appear when changing an
address or a parameter in the 7 valve.
Reconfigure.
If the error appears again, replace the 7 valve.

IdA10Fh

18

HYD (A60)

Flash memory error.

Error between the original
programme and the current
programme.
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA110h

19

HYD (A60)

Spool position supervision error.

The actual position of the spool is
too far from the position controlled
by the programme.
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA111h

20

HYD (A60)

Short-circuit on the level of the 7
valve position controller

The system providing control of the
7 valve position is damaged or
short-circuited
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA112h

21

HYD (A60)

Supply of the 7 valve above max
value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 7 valve.

IdA113h

22

HYD (A60)

Supply of the 7 valve below the
min value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 7 valve.

IdA114h

23

HYD (A60)

No response from the
microcontroller.

Supervisor damaged.
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA115h

24

HYD (A60)

Supervisor error when starting.

Supervisor not started upon tractor
starting.
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA116h

HYD (A60)

The spool of the 7 valve does
not reach the position requested
within the time set.

IdA117h

26

HYD (A60)

The 7 valve does not return to
neutral.

The 7 valve has not returned to
neutral within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
The 7 valve does not return to
neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 7 valve.

IdA118h

27

HYD (A60)

The 7 valve does not reach the
float position.

The 7 valve does not reach the
float position within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 7 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 7 valve.

IdA119h

28

HYD (A60)

The 7 valve is not at neutral
when starting.

Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA11Ah

29

HYD (A60)

The 7 valve is not at the position
desired.

The valve spool was pushed too far
in respect of the position desired.
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

IdA11Bh

30

HYD (A60)

Problem controlling the 7 valve.

The drawer moves in the wrong
direction in respect of the
command.
Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA11Dh

32

HYD (A60)

The timeout without
commanding the 7 valve has
expired.

The 7 valve is in the neutral
position as it has not been
commanded for a certain time.

IdA127h

42

HYD (A60)

Value of the 7 valve command
impossible.

Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA128h

43

HYD (A60)

Value of the 7 valve command
impossible.

Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA129h

44

HYD (A60)

Value of the 7 valve command
impossible.

Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA12Ah

45

HYD (A60)

Value of the 7 valve command
impossible.

Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA12Bh

46

HYD (A60)

Value of the 7 valve command
impossible.

Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA12Ch

47

HYD (A60)

Value of the 7 valve command
impossible.

Valve 7 returns to neutral.

Clear the error
If the error appears again, replace the 7 valve.

IdA12Dh

0

HYD (A60)

Error during the RAM test at
start.

RAM faulty.
Valve 8 returns to neutral.

The RAM memory of the 1 valve is write/read
tested when starting.
Clear the error
If the error appears again, replace the 8 valve.

IdA12Eh

1

HYD (A60)

Error upon initial commissioning
of the valve.

Faulty EEPROM.
Valve 8 returns to neutral.

This error should not occur during work, as it
appears during the initial commissioning.

IdA12Fh

3

HYD (A60)

Division by 0 internal error.

Valve 8 returns to neutral.

The calculator cannot divide by 0.
Clear the error
If the error appears again, replace the 8 valve.

IdA130h

4

HYD (A60)

Internal calculation error.

Value out of range.
Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA131h

5

HYD (A60)

Internal calculation error.

Value out of range.
Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA132h

6

HYD (A60)

Error when saving the
parameters.

Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA133h

8

HYD (A60)

Spool behaviour error.

Error between the position
requested and the controlled
position of the 8 valve spool.
Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA138h

16

HYD (A60)

Error when saving the
parameters in the EEPROM.

Memory problem.
Valve 8 returns to neutral.

Switch the ignition off and wait at least 20
seconds
If the error appears again, replace the 8 valve.

IdA139h

17

HYD (A60)

Error when setting the valve.

The 8 valve is configured
improperly.
Back to previous parameter.

This error may appear when changing an
address or a parameter in the 8 valve.
Reconfigure.
If the error appears again, replace the 8 valve.

IdA13Ah

18

HYD (A60)

Flash memory error.

Error between the original
programme and the current
programme.
Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA13Bh

19

HYD (A60)

Spool position supervision error.

The actual position of the spool is
too far from the position controlled
by the programme.
Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA13Ch

20

HYD (A60)

Short-circuit on the level of the 8
valve position controller

The system providing control of the
8 valve position is damaged or
short-circuited
Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA13Dh

21

HYD (A60)

Supply of the 8 valve above max
value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 8 valve.

IdA13Eh

22

HYD (A60)

Supply of the 8 valve below the
min value.

Check the voltage delivered by the alternator
and battery.
Clear the error
If the error appears again, replace the 8 valve.

IdA13Fh

23

HYD (A60)

No response from the
microcontroller.

Supervisor damaged.
Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

IdA140h

24

HYD (A60)

Supervisor error when starting..

Supervisor not started upon tractor
starting.
Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA141h

HYD (A60)

The spool of the 8 valve does
not reach the position requested
within the time set.

IdA142h

26

HYD (A60)

The 8 valve does not return to
neutral.

The 8 valve has not returned to
neutral within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 8 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 8 valve.

IdA143h

27

HYD (A60)

The 8 valve does not reach the
float position.

The 8 valve does not reach the
float position within the time set.
The problem may be linked with oil
viscosity (temperature too low)
reducing the performance of the
valve.
Valve 8 returns to neutral.

Let the tractor warm up and test again.
If the error appears again, replace the 8 valve.

IdA144h

28

HYD (A60)

The 8 valve is not at neutral
when starting.

Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA145h

29

HYD (A60)

The 8 valve is not at the position
desired.

The valve spool was pushed too far
in respect of the position desired.
Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA146h

30

HYD (A60)

Problem controlling the 8 valve.

The drawer moves in the wrong
direction in respect of the
command.
Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA148h

32

HYD (A60)

The timeout without
commanding the 8 valve has
expired.

The 8 valve is in the neutral
position as it has not been
commanded for a certain time.

IdA152h

42

HYD (A60)

Value of the 8 valve command
impossible.

Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

 

IdA153h

43

HYD (A60)

Value of the 8 valve command
impossible.

Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA154h

44

HYD (A60)

Value of the 8 valve command
impossible.

Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA155h

45

HYD (A60)

Value of the 8 valve command
impossible.

Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA156h

46

HYD (A60)

Value of the 8 valve command
impossible.

Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

IdA157h

47

HYD (A60)

Value of the 8 valve command
impossible.

Valve 8 returns to neutral.

Clear the error
If the error appears again, replace the 8 valve.

Error code

Native code

Sender
module

Designation

Cause/System response

Comment/Solution

 

Comments: 3
  • #3

    Kraus Hans (Sunday, 31 March 2024 10:49)

    Habe Fehlercode auf Arion 440 Code 7659, 7633, 7632, 7631, 7629, 7628 ,7606 Arion 440 Schaltet von z.B. Von C4 auf B1 während der Fahrt zurück. Fahre ich wieder ruckartig an löst sich wieder der Fehler manchmal kurze Zeit manchmal für länger .Bitte schreiben Sie mir was bedeuten diese Fehler Meldungen Habe bereits Fachwerkstatt informiert kann Ursache nicht finden.

  • #2

    BILTAC NELI SIMONA (Sunday, 19 November 2023 18:25)

    what the code error idA877h means on my AXION 850 tractor?

  • #1

    Christina Laing (Monday, 01 August 2022 12:51)

    what is fault is code Id A8D7h